110-031 PSC/EN
1
110-031 PSC/EN 25 February 2014
Operators Manual
General Purpose Water Baths
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Questions and Answers

  • N
    Nancy JonesAug 4, 2025
    Why is my PolyScience WB05A11B Laboratory Equipment not heating?
    • P
      Patricia LopezAug 4, 2025
      There are several reasons why your PolyScience Laboratory Equipment might not be heating: * The set point might be lower than the bath temperature. In this case, check the set point temperature and increase it as needed. * The bath temperature might be above the High Limit temperature. Verify that the High Limit temperature is higher than the current set point temperature and adjust it if necessary. * The liquid level in the bath might be too low. Check that the liquid level is at least 2 inches (5.08 cm) above the bottom of the tank, and add fluid if required.
  • W
    William ReevesAug 11, 2025
    What to do if my PolyScience WB05A11B has no display?
    • L
      Leslie CooperAug 11, 2025
      If your PolyScience Laboratory Equipment has no display, it could be due to: * No power to the unit. Ensure the power cord is properly plugged into a functioning electrical outlet. * The Mains Switch being in the Off position. Check that the Mains Switch on the rear of the unit is in the On position.
  • J
    Justin CarterAug 18, 2025
    Why is my PolyScience WB05A11B Laboratory Equipment heating insufficiently?
    • B
      Bryan MooreAug 18, 2025
      Insufficient heating in your PolyScience Laboratory Equipment can occur due to: * Improper line voltage. Ensure that the line voltage meets the equipment's specifications. * A recent change in set point or heat load. Allow sufficient time for the bath temperature to stabilize after making changes. * The bath cover not being in place. Make sure the bath cover is properly positioned.
  • J
    Jack BrownAug 27, 2025
    How to fix inaccurate bath temperature in PolyScience WB05A11B Laboratory Equipment?
    • J
      Jerry MorganAug 27, 2025
      Inaccurate bath temperature in your PolyScience Laboratory Equipment may be caused by incorrect calibration. Adjust the Calibration Offset as required.

Summary

Introduction

General Safety Information

Provides general safety guidelines for operating the water bath.

Safety Recommendations

LCD Display

Keypad Overview

Installation and Startup

Adding Liquid to the Bath Reservoir

Guides on filling the reservoir with appropriate fluids and levels.

Controller Setup

Setting the High Limit Value

Normal Operation

Adjusting the Set Point Temperature

How to change the desired operating temperature of the bath.

Setting and Using the Timer

Entering a Calibration Offset

Loss of Power Restart

Display Messages and Alarms

Routine Maintenance & Troubleshooting

Resetting Over-Temperature;Low Liquid Level Safety

Troubleshooting Chart

Technical Information

Reservoir Fluids

Application Notes

Service and Technical Support

PolyScience WB05A11B Specifications

General IconGeneral
ModelWB05A11B
Temperature Stability±0.01°C
Capacity5L
Safety FeaturesOver-temperature protection, low liquid level detection, high and low temperature limits
Controller TypeDigital
Power Supply120V, 60Hz

Related product manuals