- 48 -
Technical data
Advance S
Advance M
Master S
Master M
Master L
Heating power
(Water 26°C / Air 24°C)
9,4 kW
13,6 kW
9,4 kW
13,6 kW
21,5 kW
Heating power
(Water 26°C / Air 15°C)
8,0 kW
12,0 kW
8,0 kW
12,0 kW
18,0 kW
Heating power
(Water 26°C / Air -3°C)
Out of working
temperature range.
4,1 kW
7,3 kW
11,3 kW
Working temperature
range
+5°C à +35°C
-5°C à +35°C
Hydraulic connections
G1 ½’’
(½’’ male / 50 mm provided)
Water flow
3 to 6 m³/h
5 to 8 m³/h
3 to 6 m³/h
5 à 8 m³/h
7 to 11 m³/h
Nominal intensity
(Maximum)
8,6 A
(12,9 A)
12,9 A
(19,4 A)
8,6 A
(12,9 A)
12,9 A
(19,4 A)
7,2 A
(10,8 A)
Power supply
230 V / 1~
50 Hz
400 V / 3~
50 Hz
Fan
50W
850 RPM
2 x 90W
850 RPM
Refrigerant
1300 g
(R410a)
1300 g
(R410a)
1300 g
(R410a)
1900 g
(R410a)
2300 g
(R410a)
Noise level
(TUV ISO/EN 354)
57,5 dB
à 1m
59,6 dB
à 1m
57,5 dB
à 1m
59,6 dB
à 1m
59,6 dB
à 1m
37,5 dB
à 10m
36,6 dB
à 10m
37,5 dB
à 10m
36,6 dB
à 10m
36,6 dB
à 10m
Weight
63 kg
82 kg
63 kg
101 kg
133 kg
At the end of product lifetime, it must imperatively be entrusted to a qualified professional
(refrigeration technician) in order to dismantle it in accordance with the laws in force (recovery
of cooling gas, of metallic materials which can be recycled...).