SCIENTIFIC
Medical & Research
Medical and Laboratory
Refrigeration Cabinets
ENG Installation and operation manual
SWE Installations- och bruksanvisning
NOR Installasjons- og bruksanvisning
FIN Asennus- ja käyttöohjeet
FINLAND
Mukkulankatu 19,
FI-15210 Lahti, Finland
Tel.+358 20 5555 12
www.porkka.fi
NORWAY
Ringeriksveien 16
3414 Lierstranda, Norway
Tel. +47 66 98 77 77
www.porkka.no
SWEDEN
Industrigatan 21,
S-619 33 Trosa, Sweden
Tel. +46 15 63 48 40
www.porkka.se
UNITED KINGDOM
29B Greenhill Crescent,Watford
Hertfordshire, WD18 8YB, UK
Tel. +44 1923 233675
www.porkka.co.uk
ProMed MC 70, 180, 150/150 • Future MC 520, MC 720, MC 722,
MC 722GD, MC 1422GD, MC/MF 722, MF 520, MF 720, MF 722

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Porkka ProMed MC 150/150 and is the answer not in the manual?

Summary

Product Purpose and Installation

Installation Safety Warnings

Critical warnings regarding ventilation, mechanical devices, and refrigerant circuit during installation.

Controller Home Screen Details

System Setup and Configuration

Setting Time and Date

Daily Operation and Monitoring

Temperature Set Point and Alarms

Temperature Alarm Thresholds

Explanation of the internal temperature control and the function of default alarm limits.

Configuring Temperature Alarm Limits

Setting High and Low Alarms

Detailed steps to navigate service menus for setting temperature alarm limits for probe P1.

Advanced Alarm Parameter Settings

Defining Alarm Levels and Delays

Explanation of adjustable parameters like alarm levels (A1U, A1L), deviation range (A1H), and delays (A1D, d1o).

Temperature Data Recording Settings

Alarm System Management

Accessing Alarm Records

Instructions for accessing both active and recorded alarm menus via ALARM or SERVICE keys.

Viewing Active Alarms

How active alarms are displayed, navigated, and their total count shown on the controller.

Alarm History and Codes

Analyzing Alarm History

Accessing the ALARM LOG menu to review past alarm events and their details.

Understanding Alarm Codes

Comprehensive list of alarm codes, their causes, and corresponding system outputs.

Alarm Notifications and Power Failure

Operation During Power Failure

How the controller and alarms function during a power failure when the backup battery is connected.

Data Logging and USB Export

Accessing Temperature Data Log

Steps to navigate to the DATA LOG menu to view recorded temperature history.

Downloading Data Log

Overview of the data log menu and its contents, including recording status.

Exporting Data to USB

USB Data Backup Procedure

Instructions for exporting recorded controller data to an external USB storage device.

Resetting Data and Alarms

Internal Database Reset

Steps to reset all recorded values and alarms from the internal database via the SERVICE menu.

Defrost Cycle Information

Cleaning and Maintenance Procedures

Condenser and Unit Cleaning

Troubleshooting Operational Issues

Diagnosing Cooling Failures

Systematic checks to perform if the cabinet fails to maintain the correct temperature, including manual defrost.

Porkka ProMed MC 150/150 Specifications

General IconGeneral
ModelProMed MC 150/150
CategoryRefrigerator
TypeMedical Refrigerator
Capacity150 liters
Power Supply230 V, 50 Hz