PORT-A-COOL®
PORTABLE EVAPORATIVE COOLING UNIT
OWNERS MANUAL
U.S. Patent 6,223,548
U.S. Patent D 362,905
U.S. Patent 6,502,414
FOR ELECTRIC MODELS
P
AC2K482S, P
AC2K361S, P
AC2K363S,
PAC2K36HPVS,
PAC2K24HPVS, PAC2K163S, PAC2K163SFC, PAC2K163SHD
Includes Expor
t Models
PAC2K481S-230/50, PAC2K481S-220/60, PAC2K362S-230/50, PAC2K361S-230/50,
P
AC2K36HPVS-220/50, P
AC2K36HPVS-220/60, P
AC2K361S-220/60, PAC2K242S-230/50,
P
AC2K241S-230/50, P
AC2K24HPVS-220/50, P
AC2K161S-230/50, P
AC2K161S-220/60, P
AC2K161SFC-220/60

Questions and Answers

  • M
    Michael ThomasSep 23, 2025
    Why isn't my Port A Cool Freezer pump working when it has power?
    • S
      Steven DavisSep 23, 2025
      If the pump of your Port A Cool Freezer will not run, and power is available and the pump is functional, the switch might not be making closure contact. Check the continuity and replace the switch.
  • T
    Thomas HarrisAug 23, 2025
    How to fix a Port A Cool Freezer fan motor that won't run and makes no sound?
    • M
      Mrs. Shirley PattonAug 25, 2025
      If the fan motor of your Port A Cool Freezer doesn't run and makes no sound, the issue might be with the power cord, extension cord, switches, or circuit breaker. Try reconnecting the power or extension cord and resetting the breaker.
  • A
    Anthony ChapmanAug 25, 2025
    Why does my Port A Cool Freezer motor overheat and shut off?
    • N
      Nicholas MillerAug 26, 2025
      If your Port A Cool Freezer's motor is overheating, shutting off, and then restarting, it could be due to several reasons. One possibility is that the extension cord gauge is too small; replace it with a 12-gauge cord. Another reason might be obstructed inlet air or the unit being too close to a wall; ensure a minimum of 36 inches of inlet clearance. Finally, the motor itself could be faulty, requiring a replacement.
  • S
    Stephen RojasAug 27, 2025
    Why is my Port A Cool Freezer pump cycling on and off?
    • S
      Sarah LeeAug 27, 2025
      If the pump in your Port A Cool Freezer is cycling on and off periodically, it could be due to a few reasons. The extension cord gauge might be too small, so replace it with a minimum 12-gauge cord. Alternatively, the sump tank might be empty, so fill it with water. Lastly, the spray bar valve might be closed; open the valve.
  • C
    cduffyAug 27, 2025
    How to troubleshoot a Port A Cool Freezer pump that won't turn on?
    • C
      Christopher VillanuevaAug 27, 2025
      If the pump of your Port A Cool Freezer will not run when the switch is turned on, the issue might be with the power cord, extension cord, switches, circuit breaker, switch box, or connections. Try reconnecting the power or extension cord, resetting the breaker, or reconnecting in the switch box.
  • A
    Angel GraySep 15, 2025
    Why is my Port A Cool Freezer drain valve leaking?
    • T
      Tanya KellySep 15, 2025
      If water is leaking from the drain valve of your Port A Cool Freezer, it could be due to a worn washer; replace the washer. Alternatively, the stem might be worn; replace the drain valve.
  • K
    karencontrerasSep 12, 2025
    Why is my Port A Cool Freezer pump motor running but the pump isn't turning?
    • C
      Cody FowlerSep 13, 2025
      If the pump motor of your Port A Cool Freezer is running but the pump is not turning, the issue might be with the set screws on the coupling. Try tightening the set-screw or replacing the coupling.
  • P
    powellpaulSep 14, 2025
    Why is my Port A Cool Freezer fan blade not turning and making a squealing sound?
    • L
      Lisa TaylorSep 14, 2025
      If the fan blade of your Port A Cool Freezer doesn't turn and the unit makes a squealing sound, it could be due to a loose or broken fan belt; tighten or replace the fan belt. Alternatively, the fan pulley might be spinning on the shaft; tighten the pulley set screw.
  • D
    David MillerSep 5, 2025
    Why does my Port A Cool Freezer pump hum but not pump water?
    • D
      david16Sep 5, 2025
      If the pump of your Port A Cool Freezer hums when the switch is turned on but does not pump water, it could be due to a clogged inlet filter; try cleaning the filter. Another possibility is a locked pump motor, in which case you should replace the pump. There could also be other items on the circuit; remove them.
  • T
    Terry BoydSep 2, 2025
    Why is my Port A Cool Freezer overflowing or spitting water?
    • D
      Diane CarrilloSep 2, 2025
      If your Port-A-Cool Freezer unit overflows from the sump tank or is spitting water through the fan, the float valve hose might be loose at the bulkhead fitting or at the float valve; tighten the connections and/or replace the hose washers. Alternatively, the water pressure might be too high, preventing the float valve from shutting off (50 psi max.); reduce the water pressure by checking the in-line reducer. It's also possible that the float valve isn't seating properly; check for particles in the valve and replace the float valve if needed. Finally, adjust the spray bar valve to reduce excess water flow.

Summary

Introduction to Port-A-Cool

What is Evaporative Cooling?

Explains the principle of evaporative cooling and how it works using air as a sponge.

Humidity and Evaporative Cooling

Describes the relationship between air humidity and the efficiency of evaporative cooling.

Evaporative Cooling and the PORT-A-COOL Unit

Details the unit's advanced features and cooling effectiveness compared to traditional coolers.

Port-A-Cool Unit Setup Procedures

Removing and Reinstalling Cooling Media

Instructions for safely removing and reinstalling cooling pads for inspection and cleaning.

Connecting Water and Electricity

Guides on proper water hose connection and electrical hookup for unit operation.

Operating Procedures for Port-A-Cool

Unit Specifications Overview

Provides essential operational specifications for various Port-A-Cool models.

Optimal Unit Placement

Key considerations for placing the unit to ensure proper airflow and ventilation.

Filling the Water Tank

Step-by-step instructions for filling the unit's water sump tank.

Starting Pump and Adjusting Water Flow

Guides on operating the water pump and regulating flow to the cooling pads.

Starting the Fan

Instructions on how to turn on and operate the unit's fan for cooling.

Maintenance and Storage Guide

Daily Maintenance Checks

Routine operational considerations for daily unit upkeep.

Weekly Maintenance Procedures

Steps for weekly draining, cleaning, and sump tank maintenance.

Unit Storage Instructions

Guidance on preparing the unit for seasonal storage to prevent damage.

Troubleshooting and Repair

General Troubleshooting Approach

Guidance on identifying problems by system and understanding dependencies.

Fan System Troubleshooting

Common issues and solutions for fan motor problems in belt and direct drive models.

Water System Troubleshooting

Common issues and solutions for water inlet, plumbing, and spray bar systems.

Component Repair Procedures

Detailed steps for replacing fan motors and pumps on various unit models.

Replacement Parts and Warranty

Returned Merchandise Authorization (RMA)

Procedures for obtaining RMA numbers for warranty part returns and replacements.

Limited Warranty Information

Details the warranty coverage, terms, and limitations for Port-A-Cool units.

Frequently Asked Questions

Unit Assembly and Storage FAQs

Answers common questions regarding initial assembly, setup, and storage preparation.

Unit Odor and Cooling Performance FAQs

Addresses issues related to initial unit odors and troubleshooting cooling performance.

Environment and Fan Motor FAQs

Discusses optimal operating environments and fan motor maintenance queries.

Pads, Water Supply, and Moisture FAQs

Information on pad replacement frequency, water supply, and moisture production.

Appendix A: Performance Data

Temperature Output Characteristics

Provides data tables showing temperature output at various relative humidity levels.

Port A Cool PAC2K163SFC Specifications

General IconGeneral
Fan Speeds3
Cooling Capacity1000 sq ft
Power Supply115V
Air Flow1500 CFM
Weight59 lb
Cooling Area1, 000 sq ft
Water Tank Capacity11 gal
Power SourceElectric
Coverage Area1000 sq ft