18- ENG
A08202
5. Apply pipe sealant tape to the nipple on
the standpipe.
6. Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is
pointing in the direction of air flow.
7. Reapply pipe sealant to outlet pressure gauge and quick connect.
8. Reassemble outlet pressure gauge and quick connect. Orient outlet
pressure gauge to read correctly. Tighten connect with wrench.
Regulator
Arrow
Regulator
Nipple
To Replace Regulator
1. Release all air pressure from air tank.
See "To Drain Tank" in the "Maintenance"
section.
2. Unplug outfit.
3. Using an adjustable wrench remove the
outlet pressure gauge and quick connect
from the regulator.
4. Remove the regulator.
Outlet
Pressure
Gauge
Quick
Connect
Regulator