General Description
The Potter PSN series of power supplies is designed to provide the power and exibility needed for the most demanding re
system installations. The PSN-106 is a 10 Amp 24Vdc switch mode power supply design which is up to 50% more ef cient than
linear mode supplies the PSN series is your best choice for powering re system noti cation appliances and accessories. New
and retro t construction requirements for ADA compliance are easily accomplished with ample power for additional noti cation
appliances along with the ability to synchronize the noti cation appliances using built in sync generation for Potter, System
Sensor ®, Gentex® and Wheelock ® noti cation appliances. The PSN series goes even further to make retro ts easier with the
advanced QuadraSync feature which allows noti cation appliances from different manufacturers to sync with each other. You
also have the option to monitor an existing circuit by placing a reference resistor of the same value on the power supply and
continuing to monitor the circuit without changing the eld EOL.
System Features
Input voltage: 120/240VAC 50/60Hz
Output voltage 24VDC @ 10A
Six class “B” Style "Y" noti cation circuits on the PSN-106
Rated at 3 amps max each
Can be con gured as up to three class “A” Style "Z" noti cation circuits
Supervised Battery Charger: 27.3 @ 1A (supports 7-55 Ahr batteries)
Integrated battery cut-off circuitry to protect batteries from deep discharge
Two Trouble Relays (5A at 30VDC)
General System Trouble (programmable for AC delay via dip-switch)
Low AC Trouble
Diagnostic LED’s
Status LED’s for Active NAC and NAC trouble conditions
Status LED’s for Earth Fault (Amber), AC (Green), Battery Fault (Amber)
Trouble Memory feature captures troubles which have previously restored.
Synchronized noti cation appliance circuits
Potter
Wheelock®
Gentex®
System Sensor®
Con gurable output circuits (D.I.P. switch sets options for each circuit)
ANSI temporal-coded
Constant Power
Door-Holder Power
Separate DC Power Output (3A)
Two Trigger Inputs (Class A, Style Z or Class B, Style Y)
Reference EOL terminals, allows 2K – 27K EOL value to be used
QuadraSync panel wide synchronization of same or multiple brands.
PassThru mode copies input signals to output (can be used in conjunction with QuadraSync
Mounting Instructions
The standard mounting is a surface mount cabinet. The unit must be securely attached to a permanent partition using suitable
fasteners. Five mounting holes are provided to accept ¼ inch diameter screws maximum. There are seven knock outs provided.
Operating Instructions
Alarm Condition
Noti cation Appliance Circuit:
Alarm devices operate in unison with the Trigger inputs from the main Fire Alarm Control Panel (FACP). When activated by
the corresponding trigger input the associated Noti cation Appliance Circuit (NAC) will reverse polarity from a supervision state
to the alarm state and supply power to the associated noti cation appliances until the trigger is removed. Each activated NAC
will also power the L.E.D. associated with it, the L.E.D. will follow the steady or pulsing state of the NAC. The alarm-activated
outputs are reset through the operation of the reset function of the Main FACP.