What to do if the water pressure is too low in my Potterton Paramount five 115 Boiler?
- AAndrew WyattAug 17, 2025
If the water pressure of your Potterton Boiler is too low, check the water pressure and add water as needed.
What to do if the water pressure is too low in my Potterton Paramount five 115 Boiler?
If the water pressure of your Potterton Boiler is too low, check the water pressure and add water as needed.
What to do if there is no flame during the safety time in my Potterton Paramount five 115 Boiler?
If there is no flame during the safety time for your Potterton Boiler, try resetting it. If the problem happens repeatedly, contact an installer. Also, check for a lack of gas, the polarity of the mains connection, the safety period, and inspect the ignition electrode and ionization current.
What to do if the water pressure is too high in my Potterton Boiler?
If the water pressure of your Potterton Boiler is too high, check the water pressure and drain water if needed.
What to do if I have a DHW temperature 1 sensor fault on my Potterton Paramount five 115 Boiler?
If you are experiencing a DHW temperature 1 sensor fault with your Potterton Boiler, check the connection. You may also need to contact a heating specialist or try emergency operation.
How to fix an internal fault in a Potterton Paramount five 115 Boiler?
If your Potterton Boiler displays an internal fault, check the parameters, unlock LMS, or replace LMS.
How to troubleshoot an outside temp sensor fault in a Potterton Boiler?
If there is an outside temp sensor fault with your Potterton Boiler, check the connection or the outside temp sensor. Emergency operation may be required.
What should I do if my Potterton Boiler displays a flow temperature 2 sensor fault?
If your Potterton Boiler is showing a flow temperature 2 sensor fault, check the connection and contact a heating specialist.
What to do for a DHW temperature 2 sensor fault in a Potterton Paramount five 115?
If a DHW temperature 2 sensor fault occurs on your Potterton Boiler, check the connection and contact a heating specialist.
What to do if my Potterton Paramount five 115 experiences a safety temperature limiter lockout?
If your Potterton Boiler experiences a safety temperature limiter lockout, allow the device to cool down, then reset it. If the fault continues to occur, contact an installer.
What causes a Gas pressure Monitor fault in a Potterton Boiler?
A Gas pressure Monitor fault in your Potterton Boiler could indicate a lack of gas, an open contact GW, or an external temperature monitor issue.
Details critical safety precautions and warnings.
Provides detailed technical parameters for boiler space heaters.
Explains the layout and functions of the boiler's control panel.
Details essential requirements for the boiler's installation.
Explains how to make the necessary hydraulic connections for the system.
Provides instructions for making the gas connection safely and correctly.
Details the requirements for air supply and flue gas outlet connections.
Outlines the procedures and safety guidelines for electrical connections.
A checklist to ensure all steps are completed during commissioning.
Step-by-step guide for the commissioning process.
Details the settings and procedures related to gas configuration.
Explains how to modify various operational parameters of the boiler.
Details the step-by-step process for programming the boiler settings.
Describes how to select and configure different heating modes.
Explains how to adjust settings for domestic water preparation.