What to do if the water pressure is too low in my Potterton Paramount five 60 Boiler?
- HHaley FloresAug 17, 2025
If the water pressure of your Potterton Boiler is too low, check the water pressure and add water as needed.
What to do if the water pressure is too low in my Potterton Paramount five 60 Boiler?
If the water pressure of your Potterton Boiler is too low, check the water pressure and add water as needed.
What to do if there is no flame during the safety time in my Potterton Paramount five 60 Boiler?
If there is no flame during the safety time for your Potterton Boiler, try resetting it. If the problem happens repeatedly, contact an installer. Also, check for a lack of gas, the polarity of the mains connection, the safety period, and inspect the ignition electrode and ionization current.
What to do if the water pressure is too high in my Potterton Boiler?
If the water pressure of your Potterton Boiler is too high, check the water pressure and drain water if needed.
What to do if I have a DHW temperature 1 sensor fault on my Potterton Paramount five 60?
If you are experiencing a DHW temperature 1 sensor fault with your Potterton Boiler, check the connection. You may also need to contact a heating specialist or try emergency operation.
How to fix an internal fault in a Potterton Paramount five 60 Boiler?
If your Potterton Boiler displays an internal fault, check the parameters, unlock LMS, or replace LMS.
How to troubleshoot an outside temp sensor fault in a Potterton Boiler?
If there is an outside temp sensor fault with your Potterton Boiler, check the connection or the outside temp sensor. Emergency operation may be required.
What should I do if my Potterton Paramount five 60 Boiler displays a flow temperature 2 sensor fault?
If your Potterton Boiler is showing a flow temperature 2 sensor fault, check the connection and contact a heating specialist.
What to do for a DHW temperature 2 sensor fault in a Potterton Boiler?
If a DHW temperature 2 sensor fault occurs on your Potterton Boiler, check the connection and contact a heating specialist.
What to do if my Potterton Boiler experiences a safety temperature limiter lockout?
If your Potterton Boiler experiences a safety temperature limiter lockout, allow the device to cool down, then reset it. If the fault continues to occur, contact an installer.
What causes a Gas pressure Monitor fault in a Potterton Boiler?
A Gas pressure Monitor fault in your Potterton Boiler could indicate a lack of gas, an open contact GW, or an external temperature monitor issue.
General safety guidelines and warnings to ensure safe operation and prevent hazards.
Specifies the intended application of the gas condensing boilers as heat generators.
Detailed safety instructions related to specific operational aspects and installations.
Emphasizes the necessity of adhering to local and national regulations for safe appliance installation.
Covers essential requirements for boiler installation, including corrosion protection and air supply.
Details the safe and correct procedure for connecting the gas supply to the boiler by a qualified installer.
Provides essential information and safety precautions for making the electrical connections to the boiler.
Emphasizes that commissioning must be performed by a qualified installer for safety and correct operation.
Lists and explains various fault codes, their potential causes, and recommended actions for diagnosis.
Provides guidance on diagnosing and resolving common operational issues, such as burner start failures.