EasyManua.ls Logo

Power Master PM-0800LC - User Manual

Default Icon
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SOLAR
INVERTER
LCD DISPLAY
PURE SINE WAVE INVERTER
LC Series: Inverter + Battery Charger + UPS (ATS)
SLU Series: Inverter + Solar Charge Controller + Battery Charger + UPS
USER’S MANUAL
800W / 1600W / 2400W / 4000W / 6000W / 8000W
1
CONTENTS
1. INTRODUCTION .............................................……......... 2
2. SAFTY INSTRUCTION...................……...………….….... 3
3. CABLE CONNECTION..........................……..……..…..... 5
4. SYSTEM DESCRIPTION.............……........…….......…... 6
5. SOLAR INVERTER OPERATION..................................... 12
6. TROUBLE SHOOTING GUIDE.......................….….....… 17
7. OPERATION MODES OF THE SOLAR INVERTER........ 19
8. SPECIFICATION OF SOLAR INVERTER..............…....... 21
Question and Answer IconNeed help?

Do you have a question about the Power Master PM-0800LC and is the answer not in the manual?

Summary

SAFETY INSTRUCTIONS

Maintenance and Service

Highlights the risk of electric shock during maintenance and necessary precautions when working with batteries.

CABLE CONNECTION

Connection

Guidance on connecting the Solar Inverter's input and output power cords to appropriate sockets.

SYSTEM DESCRIPTION

Front Panel Description

Explains the function of each component on the front panel, including LCD display, keys, and LEDs.

SOLAR INVERTER OPERATION

Operation Procedure for LCD Model

Step-by-step guide on how to start up and shut down the Solar Inverter using the LCD model controls.

Output Voltage & Frequency Adjustment

Instructions for adjusting the output voltage and frequency settings of the Solar Inverter through the LCD menu.

Charging Current and Battery AH Adjust

Guide on how to adjust the charging current and battery AH settings for optimal battery management.

TROUBLE SHOOTING GUIDE

Troubleshooting for LCD Model

Provides a table of common inverter statuses, possible causes, and recommended actions for troubleshooting.

Troubleshooting by Status

Details troubleshooting steps for various inverter statuses like battery mode, low battery, and automatic shutdown.

SPECIFICATION OF SOLAR INVERTER

Power Master PM-0800LC Specifications

General IconGeneral
CategoryInverter
Input Voltage12V DC
Continuous Power800W
Peak Power1600W
ModelPM-0800LC
Frequency50Hz/60Hz
Protection FeaturesOverload, Short Circuit
USB Port5V/2.1A
CoolingFan Cooled