Questions and Answers

  • J
    jacksonkevinAug 12, 2025
    What to do if my Power Tech Generators PTI-15-T4F engine cranks but doesn’t start?
    • G
      ginamillerAug 12, 2025
      If your Power Tech Generators Portable Generator engine cranks but doesn’t start, here are a few things to check: * **Fuel:** Make sure you have enough fuel. If not, add fuel. * **Fuse:** Check the control box for a blown fuse and replace it. * **Fuel Relay:** Inspect the fuel relay for damage and replace it if needed. * **Fuel System:** If the fuel system lost prime, use the primer on top of the fuel filter.
  • T
    Thomas FoleyAug 20, 2025
    How to fix a Power Tech Generators Portable Generator when the engine does not crank from the local controller?
    • G
      gsinghAug 20, 2025
      If the engine of your Power Tech Generators Portable Generator doesn't crank from the local controller, consider the following: 1. **Battery:** Check if the battery is low or the terminals are dirty. Clean the terminals and recharge the battery. Replace the battery if necessary. 2. **Wiring:** Refer to the engine control wiring diagram and check the crank connections. 3. **Fuse:** Replace the blown cranking fuse with a new fuse of identical size.
  • G
    Glenn DominguezAug 27, 2025
    How to start a Power Tech Generators Portable Generator that will not start via remote panel?
    • K
      Kathryn CastroAug 27, 2025
      If your Power Tech Generators Portable Generator won't start via remote panel, make sure: the generator is in “auto” mode via the controller; the remote connection plug is properly connected.
  • D
    Donald RobertsSep 4, 2025
    What to do if Power Tech Generators Portable Generator engine starts but genset not producing voltage?
    • E
      Eugene WongSep 4, 2025
      If the Power Tech Generators Portable Generator engine starts but the genset is not producing voltage: * Ensure the main breaker is in the “on” position. * Visually inspect all generator output leads for connectivity.