EasyManua.ls Logo

PowerMax ASE59 - Administrator Mode Settings

Default Icon
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5/8
143
0123 0
Special mode:
0: normal Mode 1: simply sewing mode 2: motor initial angle measurement (Do not
remove the belt)
3: Automatically setting the pulley ratio by the CPU. (synchronizer is necessary and the belt
not removed)
144 0~31 0 Feedforward torque of motor: 0: normal functions 1-31: feedforward torque level
148 012 0 Mode of stitch correction 0: continuous1:half stitch2:one stitch
149 0~10 0 The time of chopping on for the presser foot slow down (uint is 100us)
14C 1~9999 40 The time of chopping off for the presser foot slow down (uint is 100us)
150 1100 1 The proportion coefficient of the stitches counter
151 19999 1 Maximum stitches of the counter
152 06 0
Count mode selection (For bobbin thread)
0: The counter is invalid 1: Count up by stitches. When count over, counter will be auto-
reset.
2: Count down by stitches. When count over, counter will be auto- reset.
3: Count up by stitches. When count over, motor stops and the counter must be reset by the
external switch or the P key on the panel.
4: Count down by stitches. When count over, motor stops and the counter must be reset by
the external switch or the P key on the panel.
5: Count up by trimming. When count over, panel alarms and motor stops after trimming.
6: Count down by trimming. When count over, panel alarms and motor stops after trimming.
153 1100 1 The proportion coefficient of the pieces counter
154 19999 1 Maximum pieces of the counter
155 04 0
Count mode selection (For Sewing Piece)
0: The counter is invalid
1: Count up by pieces. When count over, counter will be auto- reset.
2: Count down by pieces. When count over, counter will be auto- reset.
3: Count up by pieces. When count over, motor stops and the counter must be reset by the
external switch or the P key on the panel.
4: Count down by pieces. When count over, motor stops and the counter must be reset by
the external switch or the P key on the panel.
156 09999 0 The output chopping duty cycle of No. 1/2/3/4 solenoid in each bit.
157 09999 0 The output chopping duty cycle of No. 5/6/7/8 solenoid in each bit.
158 01 0
Counter adjustable: 0:adjustable, 1:not adjustable
161 012
Direction of parameter transfer:
0: no action 1: from operation panel to controller 2: from controller to operation panel.
162 1, 2 Restore factory setting
163 1, 2 Save current parameters as user-defined default parameters.
164 - Password
165 - Restore the default factory setting, and cover the user defined para setting,.
Note: To keep 160~164 parameters to be effective, you need press
P
key about 3-5 seconds.
3.2 Administrator Mode