manual-reset high temperature cutoff device. The cutoff will open at 160 F and
remove power to the heater should a problem occur. When the problem is corrected,
the device may be reset by depressing the button on it.
4. Depending on the ambient temperature, it may take some time for the cleaning
solution to take on a milky-white appearance which indicates that it is in
microphase. The Temperature meter and readout will show the actual
temperature, and the [OK] status indicator will be on when the set temperature
is reached. A [TEMP (F)] readout is also shown on the Operations Screen.
5. The machine provides a “Temperature Abort” function to prevent the fluid
from exceeding the recommended temperature as determined by the
manufacturer’s specification for the items being cleaned. This parameter is set
using the [ABORT TEMP] button. Enter the maximum allowable temperature
in the same manner as for the [SET TEMP] button. If the fluid temperature
reaches the maximum point, the current cleaning cycle will be aborted, and the
ultrasonic generators will be turned off. The cycle will terminate as if it had
run the full time. Allow the fluid to cool before starting a new cleaning cycle.
6. Once the desired temperatures have been entered and the fluid is at least 70
F,
the machine is ready to operate. The cycle timers are preset at the factory.
However, if the user wishes to alter the factory-set lengths, proceed to the
“Timer Setup” screen. Go to Step 8 on the next page. If the factory-set values
are acceptable, do Step 7 below and then proceed immediately to Section III.4
on Page 16 to begin operation.
7. Press the [-] button in the lower left corner of the screen to return to the
Operations Screen. Go immediately on to Section III.4.