DMX address can be set at any number within 512.
MASTER/SLAVE MODE
Many projectors can run synchronously in the Master/Slave mode by linking them with each other. First,
connect the first fixture’s DMX output to the second fixtures DMX input using XLR-XLR control cable and then connect the second
fixtures DMX output to the third fixtures DMX input, and so on until all projector are connected in this way. Eventually connect the
last fixture’s DMX output to a DMX terminator. Set 1
st
projector as the master and others are Slaves.
Start Addresses of all Slaves are 001; Operation mode of the Master can be set any mode for a Master’ and Slaves’ operation mode can
be set accordingly.
After Powered on, the group will run in Master/Slave Mode
6. OPERATION MENU
First Menu Secondary Menu Third Menu Fourth Menu
DMX Address
DMX Address=XXX
Reset
Are You Sure
Config Settings
DMX Mode
Standard 16
Extended 16
Compatible Mode
Short 8
Lamp Control
By Control Channel
By Power On
By DMX Present
Loss of DMX
When DMX is Lost
Normal time out
When DMX is Lost
Hold Last Value
Factory Settings
Fixture Type
(Press button DOWN/UP/ENTER at the
same time to enter this menu)
(WARNING: Never change the fixture
type ,otherwise the system will be
damaged!)
Special Menu
(Press button DOWN/UP/ENTER at the
same time to enter
this
menu)
Set Lock
Offset Menu
(Press button DOWN/UP/ENTER at the
same time to enter
this
menu)
Output Input Output Input
DMX 
Terminator