ENGLISH 17
RISK
Themodulemustbeinstalledtakingintoaccountitsthermalfeatures.Inorderto
guaranteeairflowaroundthemodule,sufficientroommustbeprovided between
thepanelandthemountingsystem.Thisroomwillallowheatdissipationandwill
limit the creation of condensation and humidity. Furthermore, to avoid
mechanicalfailures,modulesmustbespacedtoallowthermalexpansion.
RISK
The structure on which the modules (or a single module)shallbe mounted must
have resting points that are perfectly coplanar between themselves. When
tightening clamps orbolts forassembly, absolutely avoid applyinga torquethat
mayriskbreakingthemodule(se epoint5ofmountingprocedure).
RISK
Partial shading on modules must be absolutely
avoided, in particular a shading area which is parallel
tothecellsmayleadtoanirreversibledamageof
themodule.
photovoltaikforum.com