Features
• 3½ digit (2000 count) LCD display
• Built-in non-contact AC voltage detector
plus flashlight
• Double moulded housing
• CATIII 1000V
• 200mA/500V resettable fused current inputs and
overload protection on all ranges
• Autoranging with auto power off
Safety
International Safety Symbols
2
This symbol, adjacent to another symbol or terminal,
indicates the user must refer to the manual for further
information.
This symbol, adjacent to a terminal, indicates that, under
normal use, hazardous voltages may be present.
Double insulation
Safety Precautions
1. Improper use of this meter can cause damage, shock, injury or death.
Read and understand this users manual before operating the meter.
2. Make sure any covers or battery doors are properly closed and secured.
3. Always disconnect the test leads from any voltage source before
replacing the battery or fuses.
4. Do not exceed the maximum rated input limits.
Input Limits
Function Maximum Input
V DC or V AC 600V DC/AC
µA,
mA AC/DC
200mA/500V fast acting
resettable fuse
Resistance, diode &
continuity test
600V DC/AC