14. The error log will store up to 10 error conditions. The errors are logged with the most recent
error in position one. When a new error condition occurs, each existing error is pushed down
one position in log. If there was an error in position 10 when a new error was logged, the
error that was in position 10 will be lost.
15. Each error in the log will show the odometer reading (in miles) and the time (hour meter)
when the error occurred. The errors are displayed as;
1 ER20 1234567 MI 12345 HRS.
16. The arrows keys will allow you to scroll through the log. When the first unused position is
reached in the log, the message NO MORE ERRORS will be displayed.
17. When the QUICK START key is held for 2 seconds the message HOLD TO CLEAR
ERRORS will be displayed. If the QUICK START key is held for an additional 2 seconds, the
message CLEARED will be displayed. When the QUICK START key is released the
message NO MORE ERRORS will be displayed and all error are erased from the log.
18. Press the RESET the ENTER key to exit the information display.
19. The display will scroll either MILES: 1234567 or KILOMETERS 1234567. The reading will
indicate the total distance that has been recorded on the treadmill.
20. Press the SELECT or RESET key to continue to the hours display.
21. The display will read HOURS: 1234. The reading will indicate the total number of hours of
use.
22. Press the SELECT or RESET key to continue to the software version display.
23. The display will continuously toggle between UPPER SW VER X.XX. and LOWER SW VER
X.XX.
24. Press the SELECT or RESET key to continue to the error log display.
25. The first error log entry will scroll 1:ERR XX at 123456 MILES 12435 HOURS. If there are
no errors in the log, the message NO ERRORS will be scrolled.
26. The
▲ key will move through the log to older errors (if any). If there are no more errors, the
message NO MORE ERRORS will be scrolled.
27. Pressing and holding the QUICK START key for 2 seconds will cause the prompt CLEAR?
to be displayed, holding the QUICK START for an additional 2 seconds will clear all existing
entries from the error log. The display will confirm that the error log has been cleared by
displaying OK. The display will revert to the first log entry and show it as a null entry (1: ---).
If the QUICK START key is not held for a minimum of 4 seconds, the error log will not be
cleared.
28. Press the RESET or SELECT key to exit the information display program.