Take-Up roller Replacement
About
This procedure provides instruction to remove and replace the Take-Up roller.
CAUTION: Two running belt gauges, Precor part number 20007-101, are required.
It is important that this procedure be followed to maintain correct drive belt and run-
ning belt tension. Improper tensioning of the belt will lead to premature running belt
wear, premature driver roller bearing failure and premature Take-Up roller bearing
failure.
Procedure
Review entire procedure before starting.
1. Switch the input power OFF and unplug
1
the power cord.
2. Remove the front hood.
3. Remove the end cap and belt guard covers (see "End Cap & Belt Guard Cover Replace-
ment" on page 66.
4. Remove the left and right deck trim covers.
Removal Instructions
5. Remove running belt tension by alternately loosening the left and right Take-Up roller
mounting/adjustment bolts. Remove the mounting bolts, lift and slide the Take-Up roller
out of the running belt.
Installation Instructions
1
Disconnect a device power cord plug or cable connector from the power receptacle or outlet.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 86
6 Replacement Procedures
Take-Up roller Replacement

Table of Contents

Other manuals for Precor C956

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor C956 and is the answer not in the manual?

Precor C956 Specifications

General IconGeneral
BrandPrecor
ModelC956
CategoryTreadmill
LanguageEnglish

Related product manuals