Page 14
For technical questions, please call 1-888-866-5797.
ITEM 59137
SAFETY OPERATION MAINTENANCESETUP
Break-in Period
a. Breaking-in the Engine will help to ensure proper equipment and Engine operation.
b. The break-in period will last about 30 hours of use.
DO NOT exceed 75% of the Generator’s running wattage during this period.
• Change the engine oil after this period.
Under normal operating conditions subsequent maintenance follows
the schedule explained in the MAINTENANCE section.
CARBON MONOXIDE SHUTOFFCARBON MONOXIDE SHUTOFF
DANGER! TO PREVENT SERIOUS INJURY AND DEATH FROM CARBON MONOXIDE INHALATION:
The Carbon Monoxide sensor is an additional layer of protection only. Do not use the Generator in any area
or situation that will allow carbon monoxide to accumulate.
• FLASHING RED LIGHT:
Dangerous levels of carbon monoxide gas
have built up. Leave immediately until
area has aired out. Move Generator to
well-ventilated area before operation.
• FLASHING YELLOW LIGHT:
Carbon monoxide sensor malfunction.
Sensor needs service. Call 1-888-866-5797 as
soon as possible. Do not use the Generator until
the sensor is working properly.
NOTE: Yellow light flashes once
after starting to indicate passing self-
check and is functioning normally.
Carbon Monoxide sensor must only be serviced by qualified technician to restore it to original
settings. Do not modify or tamper with the Carbon Monoxide sensor. Not following these
instructions can result in death or serious injury due to Carbon Monoxide sensor malfunction.
Nominal 12VDC Output
1. Move the Economy (ESC) Switch
to the OFF position.
2. Only use the 12 VDC receptacle
to charge a 12 volt lead-acid
type battery using an appropriate
charge controller. (Battery and
controller not included.) The
12 VDC output is not regulated.
3. Do not connect any device
to the 12 VDC terminal that
draws more than 8 amps.
4. If this 12 VDC circuit protection is
tripped, reduce the load, and press the
Reset Button next to the outlet.