EN
6
Prexiso PLT40LI
Troubleshooting
General
1.15-135ft
0.35-40m
±1/8in
±3mm
1/16in
1 mm
2
620-690 nm, < 1 mW
Power OFF automatically
Continuous measuring
Dimension (H x D x W)
after 120 s
yes
up to 5000
measurements
14 to 140 °F
-10 to 60 °C
32 to 104 °F
0 to 40 °C
3.35 x 3.35 x 1.7 in
85 x 85 x 43 mm
Battery durability
• Clean the device with a damp,
soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning
agents or solvents.
Disposal
CAUTION
Warranty
* The typical measurement uncertainty of ±3 mm is valid for
measurements on white, diffusive, reflective targets up to
10m at low ambient light and moderate temperatures. For
distances greater than 10 m, the measurement uncertainty
could increase additionally by 0.1 mm/m. In unfavourable
conditions (such as bright sunlight, targets with poor
reflectivity, or high or low temperatures) the measurement
uncertainty could further increase up to ± 6mm for
distances below 10 m.
Potential issue table
ISSUE CAUSE ACTION
Hardware protection
after shocking
Restart the
device
Low battery
Recharge the
device
Failure to
switch on
IC000
IC255
IC301
Insufficient
On/Measure/Units
button press
Press the
On/Measure/Units
button firmly
Received signal
too weak/
Measuring time too long
Change target surface
(e.g. white paper)
Received signal
too strong
(target is too reflective)
Change target surface
Ambient light
is too strong
Running program is
not in a proper way
Restart in a proper
way by the
instructions of manual
IC401 Hardware problem
Restart the device.
If not work, contact a
local dealer
Shadow target area
(e.g. white paper)
The object is out
of rated range
Measure within
rated range
Beam is moved too fast
Move the measuring
tool slowly
Range with favourable
conditions *
Accuracy with
favourable conditions *
Care
Smallest unit displayed
Laser class
Laser type
Weight
(with batteries)
13.4 oz
380 g
Temperature range:
- Storage
- Operation
Technical Data
Flat batteries must not be disposed of
with household waste. Care for the
environ-ment and take them to the
collection points provided in accordance
with national or local regulations.The
product must not be disposed with
household waste.Dispose of the
product appropri-ately in
accordance with the national
regulations in force in your country.
Adhere to the national and country
specific regulations.Product specific
treatment and waste management can be
downloaded from our homepage.
The Prexiso PLT40LI has a two-year
warranty.
For further information on this, contact
your dealer.
This warranty is void if product is used for
commercial purposes. This warranty is
not transferable and does not cover
products damaged by misuse, neglect,
accident, alterations or use and
maintenance other than that specified in
the owner's manual. This warranty does
not apply to any expendable parts that
can wear from normal use. This