Troubleshooting
If the appliance is still not functioning correctly, contact Primus Australia’s Customer Service Centre
for your nearest authorised service agent.
SPECIFICATIONS
Model 591540 591760 591680
Capacity 40L gross 60L gross 80L gross
Weight 22kgs 28kgs 30kgs
Measurements 628 x 450 x 528mm 715 x 455 x 525mm 715 x 455 x 605mm
Problem Cause Remedy
The Compressor
runs for
1-5 minutes
and stops.
The ambient temperature is too high and
exceeds the allowable range of the freezer.
Select a well-ventilated place,
keep the freezer away from
direct sunlight.
The voltage is not in the normal range.
Switch off power and restart
when power is normal.
The compressor
runs but inner
liner does not
get cold.
The refrigerant has leaked from system.
Contact service support.
The system is blocked.
The inner liner is
very cold and the
compressor runs
continuously.
The ice layer on the evaporator is too thick. Defrost.
The door is being opened and closed
too frequently.
The door should be opened as
little as possible.
The freezer is overloaded. Remove some product.
The condenser is not well-ventilated. Select a well-ventilated place.
The controller is faulty. Contact service support.
The temperature - sensor is not correctly
located.
Contact service support.
The ambient temperature is too high
and the thermostat is set too low.
The thermostat should be set to
higher level.
The compressor
does not run.
Fridge is not connected correctly. Check power connections.
Fridge is not earthed correctly. Check earth points are correct.
The controller is faulty
(the power indicator is not on).
Contact service support.
The thermostat is set too high;
the ambient temperature is too low.
Contact service support.
Display shows
“LL”
Internal cabinet temperature is below
-28˚C.
Disconnect and allow to stabilise.
Display shows
“HH”
Internal cabinet temperature is above
+40˚C.
Disconnect and allow to stabilise.