Do you have a question about the Primus 591250 and is the answer not in the manual?
Steps to take if a gas leak is detected, including safety precautions and leak detection methods.
Specifies approved hoses, regulators, and connection procedures for propane gas.
Mandates outdoor use in well-ventilated areas and proximity to non-combustible surfaces.
Reinforces safety rules like keeping vents clear, avoiding enclosed spaces, and unattended use.
Details the requirements and best practices for safely installing the refrigerator on a stable surface.
Notes that the cooling system is developed to Australian Standards AS4555.
Explains how to connect and operate the refrigerator using a standard 240V AC power source.
Guides on initiating the cooling process and adjusting the thermostat for optimal temperature control.
Advises on safe handling of the power cord, avoiding extension cords, and proper unplugging.
Procedure for safely turning off the refrigerator when operating on AC power.
Instructions for powering the refrigerator using a 12V DC battery, including travel precautions.
Tips for maximizing cooling performance when using the 12V DC battery power source.
Prohibits operation in vehicles, boats, or enclosed areas when using liquefied petroleum gas.
Details the requirements for connecting to propane gas, including approved hoses and regulators.
Explains the three positions of the gas control/thermostat knob: MAX, MIN, and 0/OFF.
Describes the assembly including the safety pilot and electric igniter for gas operation.
Step-by-step guide for connecting, igniting, and operating the refrigerator using LP gas.
Procedure for safely shutting off the gas supply and extinguishing the burner.
Recommendations for connecting to DC and AC power outputs from generators safely.
Guidelines for storing food properly and procedures for defrosting the refrigerator.
Instructions for preparing the appliance for extended periods of non-use to prevent issues.
Guidance on regular cleaning, seal care, and mandatory professional servicing for key components.
A list of common checks to perform when encountering operational problems.
When to contact an authorized service agent for issues like flame changes or gas odors.
Details the 36-month warranty period and requirements for repairs or service.
Lists exclusions from warranty, such as loss of food or transport costs.
Provides key technical details including model, volume, dimensions, weight, and operation modes.
| operation | LP Gas, 12V AC & 230/240V AC |
|---|---|
| 12V consumption | A |
| injector size | 0.25 |
|---|---|
| gas consumption | 0.80 MJ/h |
| inlet gas pressure | 2.75 KPA |
| gross volume | 50 lt |
|---|---|
| dimensions | 630 x 475 x 525 (LxWxH) |
| net weight | 25 kg |
Loading...