The device is equipped with a multi-level battery
monitor that protects your vehicle battery against
excessive discharging when the Fridge/Freezer is
connected to 12/24 V supply.
If the Fridge/Freezer is operated when the vehicle
ignition is switched off, the Fridge/Freezer
switches off automatically as soon as the supply
voltage falls below a set level.
The Fridge/Freezer will switch back on once the
battery has been recharged to the cut in voltage
level.
Push, hold and release button until the desired
setting is reached.
Power management
POWER REQUIREMENTS
The Fridge/Freezer is designed to operate on AC and DC voltage inputs.
AC input 220-240V AC at 50Hz
DC input 12V or 24V DC
For optimum performance and ef ciency, it is important that the appliance has a reliable 15A fuse
protected DC supply in good condition. Direct connection to the battery is recommended and
reduces the risk of voltage dropping to the appliance.
It is recommended that the correct sized Automotive Electrical Cable is used for the direct connection
and that this includes a 15A fuse; do not use resettable circuit breakers. It is important that the
correct cable size is used for the installation of the DC supply as over distance the voltage can
decrease if the incorrect sized cable is being used.
DISTANCE CABLE GAUGE FOR DC INPUT
4.5m or less 2.1mm
2
(AWG14)
4.6m and over 3.3mm
2
(AWG12)
BATTERY MONITOR
Battery Monitor Control
12V DC Input Cut out Cut in
High 11.7V 12.7V
Med 10.7V 11.7V
Low 10.2V 11.2V
24V DC Input Cut out Cut in
High 24.6V 26.0V
Med 22.6V 24.0V
Low 21.6V 23.0V