MAINTENANCE
• Every month or so, it is recommended to flush the High Efficiency Reverse
Osmosis Membrane in order to maintain system performance.
1. CLOSE the Tank Valve (perpendicular with GREEN 1/4" tube).
2. OPEN the Faucet to relieve system pressure.
3. OPEN the Flush Valve (in-line with BLACK 1/4” tube).
4. Unrestricted brine (waste) water will now flow from the High Efficiency
Reverse Osmosis Membrane through the BLACK 1/4” tube bypassing
the Flow Restrictor and down the drain. This helps flush deposits and
significantly increases the usable life of the Reverse Osmosis
Membrane.
5. After 2 to 3 minutes CLOSE the Flush Valve (perpendicular with
BLACK 1/4” tube).
6. CLOSE Faucet and OPEN Tank Valve (in-line with GREEN 1/4" tube) in
order to return the system to normal operating mode.
WATER QUALITY CHECK: Your system includes a handheld TDS (total
dissolved solids) meter to monitor and maintain the water quality. After the
break in period, average TDS readings should be 20-60 ppm. Ranges vary
because the chemistry varies with different water sources.
SANITIZATION: Keep the Faucet area clean and occasionally wipe with a
sanitizing solution such as food grade hydrogen peroxide in order to prevent
contamination which can find its way to the Water Storage Tank.