INSTALLATION
START-UP:
1. CLOSE the Tank Valve and OPEN the Angle Stop Valve. If any leaks are noted,
CLOSE the Angle Stop Valve and correct before proceeding.
2. OPEN the Faucet water will slowly begin to drip out of the Faucet. This will flush
out the system.
NEW FILTER FLUSH NOTICE: In the normal production of these filter
elements, different materials are used to ensure optimal shelf life. As with any
new drinking water filtration product, we recommend a thorough 24-hour
flush of the system before product water is consumed in order to ensure
optimal taste and water quality. Failure to perform this procedure may extend
the system break-in period.
3. Check system for leaks; tighten when necessary.
4. If possible, use a flashlight to view down the drain to make sure the system is
producing waste (brine) water. You should hear the sound of water going down the
drain pipe as well as a “clicking” sound from the Permeate Pump.
5. Once the filters have been flushed, CLOSE the Faucet and OPEN the Tank Valve.
6. The Water Storage Tank will fill and the Permeate Pump will automatically shut off
in about 1-2 hours, depending on the incoming water pressure.
7. Open the Faucet and drain the Water Storage Tank.
DO NOT DRINK THE WATER FROM THE SYSTEM YET.
8. Water flow will change to dripping depending on your water pressure. Upon
complete discharge of the Water Storage Tank, turn handle to CLOSED position on
the Faucet and let the refilling process begin.
***REPEAT STEPS 6 & 7 A TOTAL OF TWO TIMES***
9. After the third tank is filled, you may drink the water.
WATER QUALITY CHECK: Your system includes a handheld TDS (total
dissolved solids) meter to monitor and maintain the water quality. After the
break in period, average TDS readings should be 20-60 ppm. Ranges vary
because the chemistry varies with different water sources.
CHECK FOR LEAKS DAILY DURING THE FIRST WEEK OF USE AND PERIODICALLY THEREAFTER.