SPECIFICATIONS
SYSTEM PERFORMANCE
Daily Production Rate 100 GPD Rated Membrane
FEED WATER REQUIREMENTS
Feed Water Potable, municipal water
Feed Pressure 40 to 80 PSI
Feed Temperature 45 Deg. F. to 100 Deg. F.
Total Dissolved Solids 600 PPM or less
Chlorine <1.0 mg/l max
pH 4-8
Turbidity <1.0 NTU (visibly clear)
SDI <5
Iron 0.2 mg/l or less
Manganese 0.03 mg/l or less
IF ANY OF THE PARAMETERS ARE EXCEEDED, PLEASE CONTACT THE SUPPIER.
PRE-TREATMENT OR SPECIAL ADJUSTMENTS MAY BE REQUIRED.
TYPICAL INSTALLATION DIAGRAM
A. Angle Stop Valve
B. 5 Micron
C. KDF + Carbon
D. Auto Shut-Off Valve
E. High Efficiency Reverse
Osmosis Membrane
F. Primary Deionization
G. Secondary Deionization
H. Remineralization
I. pH Adjustment Valve
J. Restructuring + Recharging
K. Storage Tank
L. Coconut Carbon
M. Faucet
N. Flush Valve + Flow Restrictor
P. Drain Saddle Valve