1
LOCAL AIR CONDITIONER
Model: PEL01201
Question and Answer IconNeed help?

Do you have a question about the Pro-Elec PEL01201 and is the answer not in the manual?

Summary

IMPORTANT SAFETY INFORMATION

TRANSPORTATION AND STORAGE

Transportation and labelling

Guidelines for transporting equipment containing flammable refrigerants.

Storage of equipment;appliances

Manufacturer's instructions for storing the appliance.

PRODUCT OVERVIEW

POSITIONING & INSTALLATION

Positioning

Ensuring correct placement and clearance for the air conditioner.

Ventilation Installation

Steps for installing the exhaust hose and window guide.

INSTALLATION ERRORS

CONTROL PANEL

REMOTE CONTROL

OPERATION MODES

Cooling Mode

Details on operating the air conditioner in cooling mode.

Fan Mode

Instructions for using the fan-only mode.

Timer Mode

Setting the on/off delay timer for the appliance.

Dehumidifying Mode

Using the unit to reduce humidity levels.

Sleep Mode

Activating sleep mode for quieter operation.

Compressor Protection

WATER DRAINAGE

MAINTENANCE

Cleaning

Instructions for cleaning the exterior and filters.

Filters

Procedures for cleaning and maintaining air filters.

FURTHER SAFETY INFORMATION

Information on servicing

Safety precautions for servicing refrigerant systems.

Work procedure

Safe work procedures for handling flammable refrigerants.

General work area

Ensuring a safe workspace when dealing with refrigerants.

Checking for presence of refrigerant

Methods for detecting flammable refrigerants in the air.

Presence of fire extinguisher

No ignition sources

Ventilated area

Checks to the refrigeration equipment

Checks to electrical devices

Initial safety checks

Essential safety checks before electrical component work.

Repairs to sealed components

Procedures for repairing sealed components safely.

Repair to intrinsically safe components

Working on intrinsically safe components in hazardous areas.

Cabling

Inspection of cabling for wear and environmental effects.

Detection of flammable refrigerants

Methods for detecting flammable refrigerant leaks.

Leak detection methods

Approved methods for detecting refrigerant leaks.

Removal and evacuation

Charging procedures

Decommissioning

Labelling

Labeling requirements for de-commissioned equipment.

Recovery

Procedures for safely recovering refrigerants.

TROUBLESHOOTING

TECHNICAL SPECIFICATION

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT.

Overview

This document describes the PRO-ELEC Model PEL01201 Local Air Conditioner, providing details on its function, technical specifications, usage, and maintenance.

Function Description

The PRO-ELEC PEL01201 is a portable air conditioner designed for indoor use. Its primary functions include cooling, dehumidifying, and fan-only operation. The unit is equipped with a control panel and a remote control for easy operation. It features an internal water tank for collecting condensate during cooling, which needs periodic emptying. The appliance is designed to be installed in a room with a floor area larger than 12 m² and requires proper ventilation through an exhaust hose connected to a window.

Important Technical Specifications

  • Main voltage: 220-240V ~ 50Hz
  • Rated input power: 1350W
  • Power standby mode: 1.0W
  • Cooling capacity: 3.52kW (12,000BTU/h)
  • Dehumidifying capacity: 28L/24hr
  • Air flow: 380m³/h
  • Sound power level: 65dB (A)
  • Refrigerant/charge: R290/195g
  • Global warming potential: 0.585kgCO2 eq.
  • Energy efficiency ratio (EER): 2.6
  • Energy efficiency class: A
  • Fan speeds: 2
  • Thermostat: 16-31°C
  • Recommended room floor area: 16-22m²
  • Dimensions: 325x830x370mm
  • Weight: 27kg

The appliance uses R290, a flammable refrigerant, and therefore requires specific safety precautions during installation, operation, maintenance, and disposal.

Usage Features

The air conditioner offers several operating modes and controls:

  • Control Panel and Remote Control: Both allow control over the unit's functions.
  • POWER Button: Turns the unit on or off. Upon turning on, it defaults to cooling mode with low fan speed.
  • MODE Button: Selects between cooling, dehumidifying, and fan modes.
    • Cooling Mode: Default temperature is 22°C with low fan speed. Temperature can be adjusted from 16°C to 31°C using UP/DOWN buttons.
    • Fan Mode: Selects high or low fan speed. Temperature and sleep functions are not available in this mode.
    • Dehumidifying Mode: The fan speed is low, and the sleep function cannot be set.
  • FAN Button: Selects high or low fan speed.
  • UP/DOWN Buttons: Adjust temperature in cooling mode (16°C to 31°C).
  • SLEEP Mode: In cooling mode, activates sleep function. The temperature setting increases by 1°C after the first hour and another 1°C after the second hour, then remains constant. Not available in dehumidifying or fan mode.
  • TIMER Function: Sets an on/off delay timer from 1 to 24 hours in either power-on or standby mode.
  • SWING Function: Controls the continuous left and right swing of the louvre. Pressing the button again stops the movement.
  • Compressor Protection: A three-minute delay occurs after powering on or restarting before the compressor operates, extending its lifespan.
  • Water Drainage: The internal water tank collects condensate. When full, the unit enters standby mode, and the compressor stops. The tank must be emptied by removing the plug cap and drainage plug at the rear of the unit.

Maintenance Features

Regular maintenance is crucial for efficient and safe operation:

  • Safety First: Always power off and unplug the air conditioner before any maintenance or repair activities to avoid electric shock.
  • Cleaning the Exterior: Clean the outside with a damp (not wet) cloth and dry thoroughly. Avoid using chemical solvents, abrasives, or harsh detergents, as these can damage the surface.
  • Filter Cleaning: The filters should be cleaned every two weeks to maintain efficiency.
    • Remove the air filters from the rear of the unit.
    • Lightly vacuum the filters to remove dust.
    • For exceptionally dirty filters, wash them in warm water with a mild detergent and allow them to dry completely before reinstallation.
    • Do not operate the air conditioner without the filters.
  • Seasonal Cleaning and Storage (for long periods of non-use):
    • Unplug the unit.
    • Remove the drainage plug and empty the internal water tank.
    • Plug the unit back in, power on, select fan mode, and run for two hours to dry out the interior.
    • Turn off and unplug the unit again.
    • Clean and dry the filters, then reinstall them.
    • Remove batteries from the remote control.
    • Store the air conditioner in its original carton in a cool, dry place.
    • For long-term storage, ensure the drainage pipe is fully dry to prevent mildew.
    • Cover the appliance with a plastic bag and store it out of reach of children, with dust control measures.

Safety Information (Important Considerations)

  • Flammable Refrigerant (R290): The appliance uses R290, which is flammable.
    • Store the appliance in a room without continuously operating ignition sources (open flames, gas appliances, electric heaters).
    • Do not pierce or burn the appliance.
    • Be aware that refrigerants may not have an odor.
    • The appliance must be installed, operated, and stored in a room with a floor area larger than 12 m².
    • Keep ventilation openings clear of obstruction.
    • Servicing involving the refrigerant circuit must only be performed by industry-accredited personnel competent in handling flammable refrigerants.
    • Maintenance and repair requiring skilled personnel must be supervised by someone competent in using flammable refrigerants.
    • All safety-related procedures must be carried out by competent persons.
  • General Safety:
    • Do not use means to accelerate defrosting or cleaning other than those recommended by the manufacturer.
    • Do not install or use in bathrooms or other humid environments.
    • Do not pull out the mains plug to turn off the appliance.
    • Do not place cups or objects on the appliance to prevent spills.
    • Do not use insecticide sprays or other flammable substances near the appliance.
    • Ensure proper grounding and follow local grid interconnection rules.
    • Place the appliance on a level, dry surface, at least 50cm from walls or objects.
    • Ensure the mains plug is intact and the power cord avoids trip hazards.
    • Keep air inlet and outlet free from obstructions.
    • Ensure drainage pipes are properly connected and not distorted or bent.
    • Use gentle finger pressure when adjusting wind-guide strips.
    • Keep the appliance upright when moving it.
    • Keep away from gasoline, flammable gas, stoves, and other heat sources.
    • Do not disassemble, overhaul, or modify the appliance arbitrarily.
    • Refer to a professional for repair in case of machine failure.
  • Children and Vulnerable Persons: The appliance can be used by children aged 8 and above and persons with reduced physical, sensory, or mental capabilities if supervised or instructed on safe use and understanding of hazards. Children should not play with the appliance, and cleaning/maintenance should not be done by children without supervision.
  • Supply Cord: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
  • Installation: The appliance must be installed in accordance with local wiring regulations. The exhaust pipe should be kept as short and level as possible, with a maximum extension of 1.5m, and avoid sharp bends or kinks.
  • Waste Disposal: When the product reaches the end of its life, it must be treated as Waste Electrical & Electronic Equipment (WEEE) and not mixed with general household waste. Contact local authorities for recycling schemes.

Pro-Elec PEL01201 Specifications

General IconGeneral
BrandPro-Elec
ModelPEL01201
CategoryAir Conditioner
LanguageEnglish

Related product manuals