6.4
Allocation
of
connections
for
command
and
safety
devices
Com
mand
and
safety
devices
can
be
connected
to
termina
Is
X3,
X4
and
X5.
Terminal
block
X3
Terminal
block
X4
-
CLOSE
switch
-
impulse
switch
1
-OPEN
switch
-
STOP
switch,
Wicket
door
switch,
draw-in
protection
-
Emergency
off,
slack
rope
switch
(for
optoelectronic
safety
edge
protection)
1
sequence
control
2
button
or
selector
switch
3
effective
in
dawn
direction
-
PART-
OPEN
2
-
safety
edge
protection
OPTO
-
photoelectric
drive-through
barrier
3
-
24
V
DC
1
250
mN
4
for
external
switching
devices
(connection
to
terminals
1
and
2)
wt:
white
gr:
green
br:
brown
Terminal
block
X4
(for
8.2
kOhm
safety
edge
protection)
-
PART
-
OPEN
2
-
safety
edge
protection
-
photoelectric
drive-through
barrier
3
-
24
V
DC
1
250
mN
Terminal
block
X4
(for
pneumatic
safety
edge
protection
-
pressure
sensor
test:
- A
8.2
kO
hm
resistor
must
be
connected
in
series
-
The
input
parameter
SEP
TEST
must
be
switched
on)
-
PART-
OPEN
2
-
safety
edge
protection
-
photoelectric
drive-through
barrier
3
-
24
V
DC/
250
mN
Terminal
block
X4
(for
three-wire
photoelectric
barrier)
9
8
7
6
5
4
3
-
Three-wire
photoelectric
barrier
2
1