9.2 Input operating mode
Function
DEUTSCH
RUNNING
TIME
TIME
OPEN
FOREWARN-
ING
TURNA-
ROUND
TIME
MH
RESTING
QUICK
CLOSE
RELAIS
1
RELAIS
2
RELAIS
3
RELAIS
4
Description
Select
the
menu
language
Monitoring
the
max.
running
time
for
an
open
and
close
movement.
The
running
time
must
be
set
to
be
slightly
greater
than
the
effective
running
time
of
the
door.
After
the
door
has
opened,
it
runs
in
the
CLOSE
direction
aga
in
after
the
set
time
has
elapsed.
Ata
setting
OPEN
TIME>
O,
the
impulse
function
(X3
8/9)
only
generates
commands
in
the
OPEN
direction.
Before
the
door
starts
to
move
downwards,
the
traffic
light
flashes
during
the
forewarning
time
if
automatic
closing
is
activated,
or
in
the
case
of
impulse
operation.
Standing
time
at
every
change
of
direction
MOD1:
MOD2:
ON:
When
resting
relay
OFF
(door
closed)
When
resting
relay
ON
(door
closed)
The
open
time
is
cut
short
and
the
door
closes
immediately
after
the
photoelectric
barrier
(X4
3/4)
ha
s
been
activated.
This
function
is
also
active
if
the
open
time
=
O.
OFF:
The
open
time
continues
as
usu
al
All 4
relays
can
be
allocated
to
a
rela
is
mode
of
1-28.
The
parameter
M
1-3
TRAFFIC
LIGHT
REST
affects
the
red
traffic
light
(MOD
1-
3).
MOD1:
(Red
light
1)
flashes
du
ring
forewarning
and
is
on
when
door
is
running
MOD2:
(Red
light
2)
flashes
du
ring
forewarning
and
when
door
is
running
MOD3:
(Red
light
3)
is
on
du
ring
forewarning
and
when
door
is
running
MOD4:
lmpulse
signal
at
OPEN
command
MODS:
Error
message
(ln
the
case
of
stop
messages
and
error
messages,
please
refer
to
section
1
O)
MOD6:
OPEN
end
position
MOD?:
CLOSE
end
position
MOD8:
Final
position
OPEN
denied
MOD9:
Final
position
CLOSED
denied
MOD10:
Before-end
position
OPEN
Setting
options
DEUTSCH
ENGLISH
FRANCAIS
ES
PAN
OL
NEDERLANDS
POL
SKI
CE
SKY
ITALIANO
1 -
250
Seconds
O -
600
Seconds
O -
120
Seconds
O,
1 -
2,0
Seconds
(in
1110Sec)
MOD1
MOD2
ON
OFF
MOD1-
MOD13
MOD17-
MOD28
MOD1-
MOD13
MOD17-
MOD28
MOD1-
MOD13
MOD17-
MOD28
MOD1
-
MOD28
Factory
setting
DEUTSCH
60
Seconds
0=
Auto-close
off
0,3
Seconds
MOD1
OFF
MOD6
MOD?
MOD1
MOD14