Loading...
Fault
1
error
message
System
does
not
respond
Door
trave
ls
to
the
CLOSE
end
position
when
the
OPEN
button
is
pressed
Door
travels
to
the
OPEN
end
position
when
the
CLOSE
button
is
pressed
STOP
ERROR
END
POSITION
ERROR
RUN
TIME
ERROR
SEP
ERROR
PRESSURE
SENSOR
TESTING
ERROR
ROT.
FIELD
ERROR
RS
485
AWG
ERROR
RS
485
FU
ERROR
POWER
Ca
use
-
No
voltage
supply
-
Rotational
field
at
the
motor
is
incorrect.
-The
safety
circuit
is
interrupted.
X3
1,2:
Emergency
off,
slack
rope
switch,
wicket
door
contact,
draw
-
in
protection
X6
1,2:
Interna!
On-Off
switch
X114,8:
Safety
circuit
for
door
operator
X2
81/82:
8ridge
X3
3,4:
External
stop
button
X7
1,2:
Interna!
stop
button
-The
door
has
travel
led
beyond
one
of
the
end
position
s
-The
end
positions
have
not
been
program
med
yet
-
The
program
med
running
time
has
been
exceeded
-The
safety
edge
protection
is
faulty
-
Safety
edge
protection
was
triggered
-The
PS
switch
is
not
activated
at
the
CLOSE
end
position
-
Only
special
assembly
motors
are
operated
with
an
anticlockwise
rotating
field.
-
Communications
fault
between
the
end
position
switch
and
the
controls
-
Communication
fault
between
frequency
converter
and
control
-The
power
monitoring
has
been
triggered
Rectification
-
Check
the
voltage
supply
of
the
drive
and
the
controls
-
Switch
over
the
FU
unit
termina
is
U2
and
V2
-
Check
and
then
dose
the
safety
circuit
-
Check
the
programming
of
the
end
positions
and
reset
them
if
necessary
-
Check
the
path
of
thedoor
-
Re-program
me
the
running
time
-
Check
the
safety
edge
protection
and
the
spiral
cable
-
Remove
obstruction
from
path
of
door
-
Check
the
PS
switch,
spiral
ca
ble
and
profile
-
Check
the
setting
for
the
CL
OSE
end
position
-ln
the
"
rotating
field"
input
menu,
reprogram
the
rotating
field
parameter
from
Rto
L
-
Check
the
ca
ble
and
socket
connections
-
Check
the
cable
and
socket
connections
-
Check
that
the
door
can
open
easily
and
smoothly
-
Check
AVE
(absolute
value
encoder)
plug