4. Maintenance
Do not attempt any repairs to the device or any of its accessories.
Contact us at 1-800-363-2381 for repair information.
The manufacturer will not be held responsible for the results
of maintenance or repairs by unauthorized persons.
Check the device before each use for signs of wear and/or
damage. Replace worn items (electrodes, lead wires) as required.
Type BF Applied part.
2. Electrodes
Use the device only with the lead wires and electrodes provided
or sold under the ProActive brand, following the placements
and settings prescribed by your practitioner.
It is recommended to use at minimum 4 cm self-adhesive
electrodes.
Inspect your electrodes before every use and replace as needed.
Reusing electrodes too many times may cause slight skin irritation,
low adhesion or ineffective stimulation.
• Between uses, store the electrodes in a resealable bag in a cool
dry place. It may be helpful, between applications, to moisten
the adhesive surface with a few drops of water (be careful not to
over-saturate) and then let them air-dry to help them last longer.
3. Cleaning the electrode cords
Clean the electrode cords by wiping them with damp cloth.
Coating them lightly with talcum powder will reduce tangles
and help them last longer.
Reusable, self-adhesive electrodes
19
MASSAGE PROGRAMS (PRESET ONLY) - CONTINUED
Note: Treatment length for all options below is 30 minutes.
CLEANING AND MAINTENANCE
1. Stimulator
Wipe the stimulator with a soft, slightly moistened cloth. If a more
thorough cleaning is needed, you can also moisten the cloth with
mild soapy water. Do not use any chemical cleaners or abrasive
agents to clean this device.
Therapy Site
Program
Shoulder 1 - 2 - 3 - 4
Neck
2 - 3 - 4
Bac
k 1 - 2 - 3
Elbow
2 - 3
Hip 1 - 2 - 3 - 4
Ankle 3 - 4
Foot
3 - 4
Wrist
2 - 3
Knee 1 - 2
Phase Pulse Rate
Pulse Width
Work Time R
est T
ime
(Hz)
(
s)
(s)
(s)µ
6 1
1
8 50
2.6
~220
0.6
7
1
00
50
~220
2.8
0.7
8
1
11
50
~220 3.3
0.8
Program 3 (Continued)
Phase
Pulse Rate
Pulse Width
Work T
ime R
est Time
(Hz) (
s) (
s) (s)µ
1 1
4
7
30
1
50 12.0
1
.0
~220~
2 1
69 30 1
50
~220~ 10.3
0.9
3
196
30 150
~220~
8.5 0.6
4
237 ~220~30
150
6.8
0.6
5 258
30
1
50
5.1
0.4~220~
6 290
30 1
50 5.7 0.5
~220~
7
238 30 150
6.3 0.5
~220~
8
19
7 30
150
8 0.6~220~
9 1
91
30
1
50 8.5
0.7~220~
1
0 1
68 30 1
50
9.
1
0.8
~220~
11 150
30 150
10.8
0.9
~220~
Program 4