Load cannot be sucked.
Prescribed negative pressure
cannot be achieved no more.
Negative pressure diminishes
itself too fast, when switching
the device off.
Leakage at vacuum plate by deposited
dirt between rubber seal and suction
plate.
Rubber seal wore or porously (aging
after effect of UV radiation)
Remove rubber seal from suction plate.
Clean suction plate and slot in rubber seal.
Draw up and fasten rubber seal on suction plate
again.
If necessary exchange rubber seal.
Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by an expert.
It is the contractor’s responsibility to ensure that the device is checked by an expert in periods of
max. 1 year and all recognized errors are removed ( see BGR 500).
The corresponding legal regulations and the regulations of the declaration of conformity have to be
observed!
We recommend that after checking the device, the badge “Safety checked” is put on the device.
(Order-No.: 2904.0056+inspection sticker with date).
You can receive these badges from us.
The check by an expert must be proved!