2015/02 - Indice de révision : B - Code : 29650
through the .
blue head must be oriented upwards (otherwise
impurities can gather in the mechanism and prevent
correct operation)
• LOCATION OF EES PRO PH AND REDOX PROBES:
on a by-pass loop located between the pump
to ensure that the values measured
are representative. In fact, if it is contaminated with
The probes should be mounted upstream of any
heating system: temperature changes will modify
To prevent damage to the probes by gravel or sand,
the by-pass valves should be adjusted so that the
To prevent static and interference, probe cables
should not be run in the same sheaths as the other
electrical cables.
The probe mounting tee should be mounted on a
horizontal section of the by-pass loop, and oriented
such that the pH probe is vertical. Nevertheless,
the probes should not be located at a high
point on the hydraulic circuit so that they will
remain immersed in water even if air enters the
hydraulic circuit.
• PRECAUTIONS CONCERNING THE PROBES:
• THE SUBMERGED SECTIONS OF THE PROBE:
• must always be immersed inpool water or tap
water, even when not in use (this point only
concerns the pH probe)
•
• must never be wiped
• must not be allowed to be caught in ice
• must be descaled when necessary
• THE PH AND REDOX PROBES MUST BE CALIBRATED:
• Upon reopening the pool
• Every four to twelve weeks depending on the
bather load
ff i fi fi
ff
fi
fi
faible.