Essential safety guidelines for operating, servicing, and repairing the instrument.
Defines slew rate as change in current/voltage over time, used for controlled transitions.
Explains basic operating instructions, model indication, and indicator functions like NG and REMOTE.
Details how to configure settings for CONFIG, SHORT, OPP, and OCP tests.
Explains mode indicators and the function of LOAD and DYN keys for operation control.
Details the LIMIT key's function for setting thresholds and using the NG flag.
Explains how to use the DYN key to define dynamic waveform timings like T_Hi, T_Lo, RISE, and FALL.
Explains the CONFIG key's function for sense mode selection and automatic load ON/OFF control.
Guides on setting up and performing a short circuit test, including time and voltage thresholds.
Details setting up and performing an OCP test, including current and voltage thresholds.
Guides on setting up and performing an OPP test, including power and voltage thresholds.
Details how to set system parameters like GPIB address, RS232 baud rate, and buzzer ON/OFF.
Explains the procedure for storing and recalling load settings and configurations.
Guides on creating and editing auto-sequences, including setting steps, timing, and repeats.
Explains how to run auto-sequences, interpret PASS/FAIL results, and handle NG indications.
Details protection features like Over Voltage, Over Current, Over Power, Over Temperature, and Reverse Polarity.
Summarizes RS-232 interface parameters and command similarities to GPIB.
Lists commands for setting slew rates, voltage levels, and test modes.
Lists complex commands using the PRESET format for parameter settings.
Details commands for setting slew rates, timing, and Load ON voltage.
Describes commands for setting current, power, resistance, and voltage levels.
Explains CC mode's suitability for testing load regulation, discharge characteristics, and battery life.
Explains CV mode for checking load regulation of current sources and battery voltage adjustments.
Explains CR mode's benefit for 'soft start' power supply testing.
Explains CP mode for battery evaluation, testing power output stability, and energy capacity.
Details manual control steps for performing Over Current Protection (OCP) testing.
Details manual control steps for performing Over Power Protection (OPP) testing.
Details manual control steps for performing SHORT testing, including time and voltage limits.