12
e) Is water pressure appropriate?
bar)
In case inlet water pressure is higher than 0.6 MPa, install a pressure regulator.
3.2.- START-UP
Once the installation instructions are followed (ventilation, site conditions, temperatures, water quality,
etc.), proceed as follows:
1.- Open the water inlet. Verify the no existence of leakages.
2.- Open the door and remove the protection elements on the curtain.
3.- Verify that the curtain moves freely.
4.- Connect the machine to the power supply.
5.- Push the switch on the machine front side.
6.- Verify that there are no vibrations or frictions on the elements.
7.- Close door
8.- Verify the ice cubs with the pictures below. Adjust production time switches (see table in 4.1, switches
1-4 (tf)) to make the ice cubes with the right shape.
Damages due to the lack of maintenance and cleaning operations are not included on the warranty.
Just right
Too small