Appendix 2
Over-Encapsulating Caplets into Capsules
PARTS IDENTIFICATION - CAPLET-IN-CAPSULE ATTACHMENT (ORDERED SEPARATELY)
Filling caplets inside capsules can be done
using the custom-made Caplet Fill Attachment
(ACF). The outer capsules are oriented and
separated as usual. The caplets are inserted
into the open capsules, then the outer capsules
are locked. To avoid rattling, the outer capsule
can be filled with excipient before locking.
Batch Sizes
The number of holes will differ by size. This does not affect
the instructions for use except where noted.
Capsule
Size
Number of
Outer
Capsules in
Filler
Number of
Holes in
Attachment
Number of
Cycles
A, B, D
270 90 3
AA, AAel
180 90 2
AAA
120 60 2
INSERTING CAPLETS INTO OUTER CAPSULES
1. These instructions begin after outer capsules
are oriented, separated, and seated into Filler.
2. Place the OE Guide Tray onto the Filler.
Steps for caplet orientation are similar to
capsule orientation.
3. Place the Caplet Orienter Base on the OE
Guide Tray. Align the front edge of the Caplet
Orienter Base with horizontal line I on OE
Guide Tray. Align the right edge of the Caplet
Orienter Base with the right edge of the OE
Guide Tray.
OE Guide
Tray
Caplet Tray
Caplet
Orienter Base