Appendix 3
Over-Encapsulating Capsules into Capsules
28
PARTS IDENTIFICATION - CAPSULE-IN-CAPSULE ATTACHMENT (ORDERED SEPARATELY)
Filling capsules inside larger capsules can be
done using both the ProFiller 3700 (sizes 00-5
only) and the ProFiller 3700OE (sizes AAA-D).
The outer capsules are oriented and separated
as usual. To over-encapsulate the smaller
capsules inside the outer capsules, the steps
are the same as for outer capsule orientation
except the Caps Tray is replaced with the OE
Guide Tray. The number of holes must be the
same during the orientation process for both the
outer and inner capsules.
Batch Sizes
The number of holes will differ by size. This does not affect
the instructions for use except where noted.
Capsule
Size
Number of
Outer
Capsules in
Filler
Number of
Holes in
Attachment
Number of
Cycles
A, B, D
270 90 3
AA, AAel
180 90 2
AAA
120 60 2
INSERTING CAPSULES INTO OUTER CAPSULES
1. These instructions begin after outer
capsules are oriented, separated, and seated
into Filler.
2. Place the OE Guide Tray onto the Filler
Base.
3. Place the Capsule Orienter Base on the
OE Guide Tray. Align the front edge of the
Orienter Base with horizontal line I on OE
Guide Tray. Align the right edge of the
Orienter Base with the right edge of the OE
Guide Tray.
Orienter
Base
Orienter
Tray
OE Guide
Tray