High Pressure Coolant System Packages
Installation & Operation Manual
HPC Model PFMF 120-10
PFMF 70-20
PFMF 70-15
PFMF 30-20
PFMF 20-20
Rev.20161107 V5.0E
The contents of the manual is subject to change without notice for improving quality.
* The products in the photos may be different from the actual products.
1156, Dudong-ro, Dudong-myeon, Ulju-gun, Ulsan, Korea.
TEL : +82-52-289-4035 FAX : +82-52-289-4037 www.kemtech.co.kr

Questions and Answers

  • A
    Anthony CastroAug 10, 2025
    Why is there significant noise and low pressure at the high-pressure pump in my profluid HPC PFMF 70-20 Industrial Equipment?
    • J
      Judy CainAug 10, 2025
      If you're experiencing significant noise and low pressure at the high-pressure pump of your profluid Industrial Equipment, first check the tubing for any leakage, damage, or loosening that might be introducing air into the inlet tubing line. If the tubing is fine, the toothed wheel at the high-pressure pump may be worn, requiring replacement of the high-pressure pump. Also, ensure that you are using the standard filter bag supplied; incorrect specifications can cause this issue. Use the standard component supplied from KEMTECH.
  • C
    Christopher RubioAug 15, 2025
    What to do if there is a filter replacement alarm in my profluid HPC PFMF 70-20 Industrial Equipment?
    • M
      Mary PhamAug 15, 2025
      To address a filter replacement alarm in your profluid Industrial Equipment, start by inspecting the bag filter for clogging and replace it if needed. After replacing the filter, open the dirty tank drain valve to remove the cutting oil. Also, inspect the level switch and replace it if it's malfunctioning.
  • J
    janetwilliamsAug 22, 2025
    What to do if the high-pressure pump is inoperative in my profluid HPC PFMF 70-20?
    • S
      Stacey FergusonAug 22, 2025
      If the high-pressure pump in your profluid Industrial Equipment is inoperative, first check the power supply. Ensure that the rated voltage (220V, 3-phase) is normally supplied and that the MCCB or EOCR of the machine hasn't shut off. Also, check for any cable disconnection or removal of the terminal from the power cable. If power is supplied but the motor is inoperative, check the resistance between the motor coils; replace the motor if the resistance is zero or infinite.
  • R
    Richard WalterAug 27, 2025
    How to fix an alarm from the level switch at the clean tank in profluid HPC PFMF 70-20?
    • Z
      zspenceAug 28, 2025
      If you are getting an alarm from the level switch at the clean tank of your profluid Industrial Equipment, inspect the bag filter and replace it if it's clogged. Check the level switch itself and replace it if it's malfunctioning. Make sure the coolant supply pump is operating correctly; repair or replace it if needed. Also, check for any clogs in the tubing at the inlet of the coolant supply pump, cleaning the filter at the pump inlet or the main coolant tank. Finally, verify that the tank flow rate is sufficient; if not, replace the coolant supply pump with one that has a flow rate greater than 40 LPM.
  • P
    Patricia HannaSep 2, 2025
    How to fix leakage from the high-pressure pump in profluid Industrial Equipment?
    • B
      Becky BlankenshipSep 2, 2025
      If there is leakage from the high-pressure pump of your profluid Industrial Equipment, the most likely cause is a worn seal. Replace the seal to resolve this issue.

Summary

Chapter 1 Precautions for Safety

Chapter 3 Nomenclature of Each Component and Basic Specifications of HPC Model PFMF 000-00

3-1. Nomenclature of components on the front panel

Identifies and labels components located on the front panel of the system.

3-1. Nomenclature of components on the rear panel

Identifies and labels components located on the rear panel of the system.

3-2. Nomenclature of components of the pump

Identifies and labels the components of the pump unit.

Chapter 4 Cautions before Installation

Chapter 5 Installation

Fixing the system

Instructions for securely fixing the HPC system on a flat floor.

Tubing

Recommendations for tubing installation, considering distance, space, and coolant flow.

Tubing at the inlet (coolant supply inlet)

Specific guidelines for using tubing at the coolant supply inlet.

Chapter 6 Electric Wiring

Chapter 7 Trial Run

Chapter 8 Pressure Setting and Operation of Pressure Control Valve

Chapter 10 Filter Replacement

Chapter 11 Maintenance and Repair

Chapter 12 Troubleshooting

profluid HPC PFMF 70-20 Specifications

General IconGeneral
Brandprofluid
ModelHPC PFMF 70-20
CategoryIndustrial Equipment
LanguageEnglish