USER MANUAL
ONLINE UPS
UPS I1000/2000/3000
Uninterruptible Power Supply
www.pinnacle.co.za

Questions and Answers

  • L
    Linda TaylorSep 9, 2025
    What does it mean when Proline I2000 UPS signals 'Battery Low'?
    • H
      Harold PadillaSep 9, 2025
      If your Proline UPS signals 'Battery Low' and you hear an audible alarm every second, it means the battery is almost empty.
  • A
    ashlee94Sep 12, 2025
    What to do if Proline I2000 shows ambient temperature high?
    • T
      Theresa KentSep 12, 2025
      If your Proline UPS displays 'Ambient temperature high', it indicates that the ambient temperature is too high. Check the environment ventilation.
  • B
    Brian DixonSep 12, 2025
    How to resolve 'Site Fail' error on Proline I2000 UPS?
    • R
      Richard SmithSep 13, 2025
      If your Proline UPS shows a 'Site Fail' error, it means the phase and neutral conductors at the input of the UPS system are reversed. Rotate the mains power socket by 180° or correctly connect the UPS system.
  • T
    Thomas MckenzieSep 15, 2025
    What does 'Inverter Short' mean on Proline I2000?
    • W
      wmcgrathSep 15, 2025
      If the Proline UPS displays 'Inverter Short', it means there is an output short circuit. Remove all loads, turn off the UPS, and check the output of the UPS and loads for any short circuits. Ensure the short circuit is removed and the UPS has no internal faults before turning it on again.
  • T
    Tammy GoodwinSep 16, 2025
    What to do if Proline I2000 shows EPO active?
    • S
      sandracookSep 17, 2025
      If your Proline UPS shows 'EPO active', it means the EPO (Emergency Power Off) function is enabled. Plug into the EPO switch.

Summary

Safety and EMC Instructions

Installation Procedures

Guidance on installing the UPS, including acclimatization and placement.

UPS Operation Guidelines

Maintenance, Servicing, and Faults

UPS Panel Description

Connection and Operation

UPS Input Connection

Details UPS input connection requirements and recommended breakers.

UPS Output Connection

Battery Charging Procedure

Turning On the UPS

UPS Cold Start Procedure

UPS Test Function

Turning Off the UPS

Audible Alarm Mute Function

External Battery Connection for S Models

External Battery Connection Details

UPS Operating Modes

Line Mode Explained

Details the Line mode display and conditions.

Battery Mode Operation

Bypass Mode Operation

No Output Mode Operation

Abnormal Mode Indication

Setting UPS Parameters via LCD

Troubleshooting Guide

Troubleshooting Common Problems

Maintenance Procedures

UPS Operation Notes

Mentions no user-serviceable parts and when to contact the dealer for battery replacement.

Battery Replacement Process

Details battery replacement by qualified personnel, including shutdown and testing.

Technical Data: Electrical Specifications

Technical Data: Backup Time

Communication Ports Overview

Software: WinPower Monitoring Tool

Proline UPS I2000 Specifications

General IconGeneral
Capacity2000VA / 1200W
WaveformSimulated Sine Wave
Operating Temperature0°C to 40°C
Weight12.5 kg
Output Voltage230V AC
Frequency50/60Hz
Transfer TimeTypical 4-8ms
Battery TypeSealed Lead-Acid (SLA)
Battery Recharge Time4-6 hours
ProtectionOverload, and overcharge protection
Communication InterfaceUSB
Humidity0-90% RH non-condensing
Storage Temperature-15°C to 45°C