DC-800
Double Chamber Vacuum Packaging
Machine
Operation Manual
Version 6.9.1
1915 E. Acacia Street, Ontario, CA91761, U.S.A
TEL : 1-909-923-3888
FAX : 1-909-923-3588
http://www.promarksvac.com
S/N: QC SIGNATURE:

Questions and Answers

  • J
    Jeffrey HendersonAug 12, 2025
    Why is there insufficient vacuum in the bag with Promax DC-800 Packaging equipment?
    • D
      Dawn HarrisAug 12, 2025
      Insufficient vacuum in the bag may occur if the bag is leaking, has been punctured by sharp corners on the wrapped product, or is simply too large. To resolve this, replace the bag. If sharp corners are the issue, replace the bag and use a thicker one. If the bag is too large, replace it with a smaller one.
  • D
    David FordAug 17, 2025
    How to fix burnt marks or bubbles on the sealing area of Promax DC-800 Packaging equipment?
    • M
      Maria KiddAug 17, 2025
      Burnt marks or bubbles in the sealing area can be caused by oil, meat juice, dirt, or excessively long or high sealing time/temperature. Clean and remove any foreign substances from the sealing area. Then, adjust the sealing time or temperature to be shorter or lower.
  • J
    James MccartyAug 23, 2025
    What to do if a vacuum bag is easily pulled apart by hand after using Promax DC-800?
    • S
      Stacy VasquezAug 23, 2025
      If a vacuum bag is easily pulled apart, the sealing time or temperature is likely too short or low. To fix this, adjust the sealing time or temperature to be longer or higher.
  • E
    Ernest Schmidt IIAug 30, 2025
    Why doesn't the vacuum pump run on my Promax Packaging equipment?
    • J
      Jennifer SimmonsAug 30, 2025
      The vacuum pump may not run if the power supply does not match the power demand indicated on the back of the machine. Reconnect to the correct power source to resolve this.
  • M
    Matthew ShawSep 4, 2025
    What to do if the control panel is working but the vacuum pump won't start on Promax DC-800 Packaging equipment?
    • S
      sharonrojasSep 4, 2025
      If the control panel functions normally but the vacuum pump does not start, the KM1, QM1, MCB1, or MCB2 protectors may be disconnected. Check each part and turn on the switch or reconnect if necessary.