19
Problem Cause Correction
No or improper sealing.
NOTE : Please do not adjust
sealing longer than regular time,
or it will reduce the life of Teflon
tape and silicone rubber.
Sealing wire is broken.
Sealing wire is loose.
Insufficient pressure.
Sealing transformer is damaged.
Teflon tape or silicone rubber is
damaged.
Sealing time and cooling time are
too short.
Sealin
pressure is too low.
Replace it.
Tighten it.
Pressure bar is damaged, replace
it.
Replace it.
Replace it.
Adjust to proper time.
Re
lace the
ressure ba
.
Lid does not close. Vacuum valve is damaged.
Limit switch is disconnected or
damaged.
Replace it.
Reconnect or replace it.
5.2 25PIN D Type Terminal Wiring Connection
Instructions
P IN
NO
FUNCTION
PIN
NO
FUNCTION
1
AC24V Input
—
For
Internal
13
External
DC24V
Rectificated
2
AC24V Input
—
For Internal
14
External
DC24V
Rectificated
3
AC24V Input
—
For External
15
Sealing Bar
2
Heat
Contact
Relay
Contact
4
AC24V Input
—
For
External
16
Pulse Soft
Air
Contact
Relay
Contact
5
Air Inlet
Valve Relay
Contact
17
x
6
Sealing Press
Bar Gas Flushing
Relay
C
on
t
ac
t
18
x
7
Sealing Bar
1
Heat
Relay
Contact
19
x
8
External Special
Gas Valve
Relay
Contact
20
x
9
Vacuum
Valve
Relay
Contact
21
Over Relay Input
Same As
25
External
Input
10
COM
Relay
Contact
22
Internal
Grounding
External
Input
11
Internal
Grounding
External
Input
23
COM
point Relay
Contact
12
Vacuum
Lid
Signal
Input
External
Input
24
Vacuum
Motor
Contact
Relay
Contact
25
Over Relay Input
Same As 21
External
Input