Lockout Clearing Procedure
The lockout must be cleared by turning the ‘Fan Only’ setting on the control panel, ‘on’, ‘off
and ‘on’ again within 2.5 seconds. If the first lockout reset attempt is unsuccessful, you can
retry an additional 4 times. If the lockout still will not clear (identified by a solid LED), please
turn off the heater, check the heater for faults, power up the heater and then further lockout
reset attempts can be made.
LOCKOUTS
The installation must be inspected and tested annually by a registered person (see item a)
on page 2) and any servicing and cleaning identified carried out. Servicing and removal of
the main cover must only be performed by an approved fitter or the manufacturer.
The heater should not be left for long periods without use. It is advisable to run the unit for
short periods throughout the summer.
The exhaust and inlet pipes should be inspected periodically for damage and any build-up
of dirt around the ends. Clean or replace as necessary.
The heater, its gas supply, and flues for the products of combustion are to be inspected in
accordance with national regulations or if these do not exist, the manufacturer’s
recommendations, however, it is advised that this should be done at least annually.
MAINTENANCE
Question and Answer IconNeed help?

Do you have a question about the Propex Heatsource HS2000 and is the answer not in the manual?

Propex Heatsource HS2000 Specifications

General IconGeneral
Voltage12 VDC
Fuel TypePropane
Heat Output2.0 kW
Current Consumption1.4 A
TypeForced Air

Summary

Maintenance

Lockout Clearing Procedure

Procedure to reset the heater after a lockout condition by turning the fan control to 'off', 'on', and 'off' again within 2.5 seconds.

Safety Warnings and General Information

Fault Finding

Wiring Instructions

Gas Connection

Operation

Fitting the Heater