(14)
Counter
Selector
Switch
Press
the
switch
(
A
)
to
external
counter.
Press again
(
1
)
to
internal
counter.
(15)
External
Counter
¡Ñ
Counter
input
connector
for
the
external
signal
input.
(16)
AM
Switch
(ON
J.
,
OFF
J.
l
._
Press
this
switch
(
.1
)
for
amplitude
modulation.
The
MOD
IN
terminal
(17)
Is
used
to
input
modulation
signals.
(17)
MOD
IN
Terminal
This
is
the
input
terminal
for
amplitude
modulation.
lt
provides
an
input
lmpedance
of
about
10k
ohms,
a
frequency
range
of
DC
to
1
MHz,
and
a
maximum
input
voltage
of
j:
10V
(AC+DC)
(18)
LOG
l
J.
l/LIN
(
Jn
)
Switch
With
the
MODE
switch
(S)
set
to
SWEEP,
the
LOG/LIN
switch
enables
Iogarithmic
sweep
or
linear
sweep
to
be
selected.
(19)
SWEEP
(
1
)/SET
START
l
L
)
Switch
This
switch
is
used
to
set
the
sweep
start
frequency
with
the
MODE
(S)
set
to
SWEEP.
When
the
switch
is
pressed
(
...
)
for
SET
START,
the
sweep'is
stopped
at
the
sweep
start
frequency.
Then,
connect
the
generator
output
to
a
frequency
counter
or
oscillo-
scope,
and
specify
a
sweep
start
frequency
by
using
the
START
knob
After
the
frequency
IS
set,
the
sweep
can
be
resumed
by
setting
the
switch
to
SWEEP
(
J.
l
The
sweep
stop
frequency'
IS
set
by
using
the
FREQ.
dial.
(20)
Start/MOD
Level
Control
This'
IS
used
to
set
the
sweep
start
frequency
and
to
change
the
amplitude
modulation
level.
(21)
Time
01-
lOs(
l.
100ms(.l
)Switch
This
switch
IS
used
to
switch
the
time
ranges
for
burst
gate
or
sweep
when
the
MODE
switch
(5)
IS
set
to
BURST
or
SWEEP.
(22)
AM
Carrier
Level
Control
This
IS
used
to
adjust
carrier
levels
for
amplitude
modulation.
With
a
setting
around
carrier
waves
are
suppressed
and
a
double
sideband
(DSB)
Is
obtained.
(23)
Symmetry
(Pull-0n)NariabIe
Variable
(outer
knob):
This
is
used
to
adjust
the
burst/sweep
time
contínuously
in
the
range
selected
by
the
TIME
switch
Turning
the
VARIABLE
counterclockwise
decreases
the
time.
Symmetry
(pull-on)
(inner
knob):
Pull
out
to
adjust
the
ON/OFF
time
for
a
burst
and
sweep
time
(both
ways).
When
this
knob
is
pushed
in,
the
time
ratio
is
50:50.
Í
i
í?
i
s‘xuwak-e
,,
ya”?
“-
«Types,»
"¿a
sue,
¡“a