C5
How to Install Electric Load Sensor
Proteus C5 WiFi Electric Load Sensor monitors current
flowing through a power cord to determine whether the
load is ON or OFF. After you have completed the Wi-Fi Setup
process outlined in the Quick Start Guide, Clamp the sensor
node to the power cord, and connect the node to the base
unit by either directly plugging it into the stereo port or via
the extension cord included.
Emails, Calls, Text Alerts
You can add your phone numbers, multiple emails
to the notification list. No matter where you are,
you can be in the know when an alarm is tripped.
Testing Your Sensor
After the installation is complete, depending on the
type of load you are monitoring, read further on
how to configure the settings, and test your sensor.
AC Power Outlet
Power Cord to
the Electric Load
C5 Sensor Node
Extension Cord
Electric Load
(representative only)
Notes
1. After setting up your sensor, if it starts to beep
or goes to alarm, don’t worry. The sensor may need
additional settings update to match with the type
of load you have. See next page for details.
2. Proteus C5 is an electric load ON/ OFF sensor. It
cannot calculate the power / energy used by the
load
3. Proteus C5 monitors current, and not voltage.
4. Proteus C5 requires atleast 500mA to detect ON.
Question and Answer IconNeed help?

Do you have a question about the Proteus C5 and is the answer not in the manual?

Proteus C5 Specifications

General IconGeneral
BrandProteus
ModelC5
CategoryAccessories
LanguageEnglish

Summary

Proteus C5 Electric Load Sensor Installation

Installation Steps

Guide on clamping the sensor node to the power cord and connecting to the base unit.

Usage Notes and Alerts

Covers important operational notes, alarm behavior, and notification setup.

Sensor Testing Procedure

Post-installation steps to confirm sensor functionality and settings.

Sensor Configuration and Operation

Understanding Electric Load Types

Categorization of electrical loads based on their operational patterns for configuration.

Configuring Proteus C5 Settings

Detailed guide on setting Normal State, Monitoring Schedule, and Alarm Delays.

Sample Configuration 1: Normally OFF Load

Example setup for a normally OFF load like a sump pump.

Advanced Configuration and Monitoring

Sample Configuration 2: Normally ON Load

Example setup for a normally ON load like a main electric motor.

Sample Configuration 3: Cycling Load

Example setup for a cycling load like a refrigerator, including learning stage.

Monitoring Power Outage

How to configure the sensor to notify if power or Wi-Fi is lost.

Troubleshooting and Support

Basic Troubleshooting Tips

Addresses common issues like the sensor light not turning on or false alarms.

Additional Help and Contact

Information on where to get further assistance for sensor setup and operation.