1
teChniCal speCifiCations:
Power Supply:
Voltage: 12 – 18 VDC or AC
Current Consumption: 300mA Maximum
Relay Outputs (resistive load):
Maximum Switching Voltage: 30 VAC/DC
Maximum Switching Current: AC: 10 A (NO) / 3 A (NC)
DC: 5 A (NO) / 3 A (NC)
Maximum Switching Capacity: 1250 VA (NO)
375 VA (NC)
Minimum Permissible Load: 10 mA at 5VDC
Contact Resistance: 100 mΩ Maximum
Life Expectancy:
Mechanical: 10,000,000 operations
Electrical: 200,000 operations minimum
(at maximum rated load)
Environmental:
Ambient Temperature: -40°C to +80°C (-40°F to 176°F)
Ambient Humidity: 0% to 100%
Note: The humidity inside the housing for any VP device cannot exceed
100% and must be noncondensing.

Related product manuals