To calibrate the temperature of the machine, input the current room temperature in the
dialog box when the internal temperature of the machine is consistent with the room
temperature, click "save" to finish the room temperature calibration, and click the
back button to enter the main menu interface.
3. Click the "Temp Curve" button to enter the following interface:
There are 8 default solder paste welding curves of the machine. Users can select the
appropriate welding curve according to the process requirements of their own solder
paste.click “perform”,pops up preheating mode dialogue,click “sequential”
All
temperature zones will not be started at the same time to avoid excessive starting
current
or“synchronous
All temperature zones start synchronously and run with full
load
to start.Click the return button to enter the main menu interface after selection.
4. On the main interface,click “Start Heating”,pops up “Preheating Mode”
dialogue,click “sequential”
All temperature zones will not be started at the same time
to avoid excessive starting current
or“synchronous”
All temperature zones start
synchronously and run with full load
to start.The machine runs the selected curve.