1.
Insert the Battery Pack (11) along the rail into the APS charger (18)
slot as far as it will go. The APS charger is supplied with your device or
purchased separately.
2.
Point A on the battery and point B on the charger should match.
3.
Connect the Micro USB Type-B plug of the USB cable (22) to the port
(19) of the charger (18).
4.
Connect the second plug of the USB cable (22) to the USB port on the
power adapter (23).
5.
Plug the device into a 100-240 V socket.
6.
The LED indicator (20) will display battery charge status.
7.
Wait until the battery is fully charged (LED indication (20): ).
8.
Two batteries* can be charged at the same time: the second slot is
designed for it.
(20) LED Indicator** Battery Charge Status
Battery level is from 0% to
10%. Charger is connected to a
power supply.
Battery level is from 0% to
10%. Charger is not connected
to a power supply.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pulsar Merger LRF XP50 and is the answer not in the manual?

Pulsar Merger LRF XP50 Specifications

General IconGeneral
Objective Lens Diameter50 mm
Detection Range1800 m
Laser RangefinderYes
Wavelength905 nm
Built-in Memory16 GB
Wi-FiYes
Stream Vision 2Yes
Waterproof LevelIPX7
Display Resolution1024x768
Video / Photo FormatMP4, JPG
External Power SupplyUSB-C
Operating Temperature Range-25 … +50 °C