TECHNICAL SPECIFICATIONS:
Dimensions: 0.99 x 0.72 x 4.29 Inches
Battery capacity: 880mAh
Battery discharge current: 8A discharging
Charging port: USB-C
Charging Voltage: 5V 1A
Temperature setting: 440°F / 410°F / 390°F / 360°F
Heating element: 316L stainless steel 
OPERATING INSTRUCTIONS 
You will need to fully charge the Pulsar
® 
Syndr
™ 
vape 
before first use. The charging port is located 
underneath the silicone cover by the power button. 
The cover does not come all the way off. Simply 
pull down from the top and pivot the cover off to the 
side so it’s out of the way. Use included USB-C 
cable and compatible charging brick to charge the 
device. The light will turn red while charging and 
green when fully charged. Once the device is 
charged, unplug from the cable and cover the 
USB-C port. 
Upon first use, it is recommended to run this device 
through a heating cycle without any material in the 
chamber to burn off any manufacturing residue 
which may affect taste or smell during normal use.
Open the bottom heating chamber by pushing one 
side with your thumb. It should be removed with 
ease. Fill the chamber to the top of the stainless steel 
chamber. This is the maximum fill for the unit. 
Once loaded, replace the bottom chamber. Hold the 
power button for 5 seconds to power on the device. 
Power button is located just below the charging 
cover. You will notice the power button insignia. You 
will feel the haptic feedback (vibration) and also see 
the light pulsate when turned on. The pulsating light 
signifies the device heating up to the preferred 
temperature (approximately 30 seconds). At this 
time, to find your preferred heat setting, press the 
power button one time for each heat setting. Cycle through the 
settings to find your desired setting. Once you find your desired 
temperature setting then the device will heat to that setting.
Yellow Light - 360°F 
Green Light - 390°F
Blue Light  - 410°F
Red Light - 440°F
The unit will vibrate twice once the device achieves your set 
temperature. The Pulsar insignia will also turn a solid color 
instead of the flashing during the pre-heat cycle. This is when 
you can begin your vape session. When you power the device 
back on after your last use, the last heat setting you set it to will 
be present. To change the setting follow the instructions above. 
To end your session before the sesh timer times out, simply 
hold the button down for 5 seconds to power off the device. 
When the device is powered off, you can view the battery life by 
pressing the power button once. 
Green Light - 75% or higher
Blue Light - 30%-75%
Red Light - 30% or below
PRO TIPS
Vape timer is set to 3 minutes for the Yellow, Green, and Blue 
settings. The Red setting is set to 2 minutes. If you do not 
complete your session at this time, take the bottom connector 
off and stir with the included stir/brush tool. 
The device does not support pass-through charging.
To maximize efficiency, whenever possible, allow the unit to 
cool completely before the next session. 
Empty the cashed material at the end of each session and use 
the cleaning brush to remove any excess particles from the 
heating chamber. This will keep the unit clean for your next 
session. 
CLEANING INSTRUCTIONS
First remove the bottom chamber cover and the silicone 
mouthpiece insert.
Use the cleaning brush to clean the mouthpiece opening and 
the bottom chamber opening.
Insert the poker side of the cleaning tool all the way into the 
mouthpiece opening to push out the screen.
Use the isopropyl cotton swabs to push through the airpath 
chamber, while also wiping out the bottom chamber and 
mouthpiece opening. Allow to air dry after cleaning.
To reassemble, put the screen back into the bottom chamber 
and press with the poker tool side of the cleaning tool. It should 
lock into place.
Place the mouthpiece insert back into the mouthpiece opening.
IMPORTANT SAFETY WARNINGS 
• Do not expose to extreme temperatures or direct sunlight. 
• Do not drop the device or accessories. 
• Do not drop or submerge in any liquid. 
• Do not modify the electronics in any way. 
• This device is intended for adults only. Do not sell or provide to minors. Keep all parts, concentrates, herbs, and liquids 
away from children and pets. This is not a medical device and is not intended to diagnose, treat, mitigate, cure, or prevent 
any ailment, disease, or other conditions. Consult a physician before use, especially if you suffer from heart disease or any 
other medical condition, or if you are pregnant or breastfeeding. Failure to follow any of these instructions could result in 
product damage, property damage, personal injury, and may void warranty.
LIMITED WARRANTY
Pulsar
®
 products are guaranteed from manufacturer defects or malfunction from the original date of purchase for a period of 
one year. This limited warranty protects against manufacturer defects under normal use and does not apply to normal wear 
and tear, improper use, and accidental damage from dropping or submerging in liquid, improper cleaning, neglect, or any 
other damage that is not a result of defective materials or workmanship. If your device qualifies, we will replace, at our 
discretion and expense, any defective parts or materials. Purchaser must provide a copy of the original dated sales receipt 
and may be required to provide shipping to return defective parts or materials. We intend to complete all replacements 
within 7 business days, although this timeframe may vary depending on shipping, replacement part availability, or other 
related factors. The lawful and proper use of this device is a condition of sale. Any improper use of the device will void the 
warranty. Warranty is non-transferable. This warranty gives you specific legal rights, and you may also have other rights, 
which vary from state to state.