Calibration
mode
selection
.
Calibration
enables
the
device
to
equalize
the
microbolometer
background
temperature
and
eliminate
the
image
flaws
(
such
as
vertical
bars
,
phantom
images
,
etc
.).
There
are
three
calibration
modes
:
Manual
,
Semi
-
Automatic
and
Automatic
.
The
selected
calibration
mode
is
displayed
in
the
status
bar
(
see
Status
Bar
section
).
Select
the
required
mode
in
the
Calibration
Mode
menu
item
:
Press
and
hold
the
MENU
11
button
to
enter
the
main
menu
.
Use
the
UP
10/
DOWN
12
buttons
to
select
the
Calibration
Mode
icon
.
Press
the
MENU
11
button
briefly
to
enter
the
submenu
.
Use
the
UP
10/
DOWN
12
buttons
to
select
one
of
the
calibration
modes
described
below
.
Press
the
MENU
11
button
briefly
to
confirm
the
selection
.
M
mode
Manual
Close
the
lens
cover
1
.
Press
the
ON
/
OFF
9
button
briefly
.
Open
the
lens
cover
1
after
the
calibration
is
completed
.
SA
mode
Semi
-
Automatic
)
The
user
independently
determines
the
need
for
calibration
(
according
to
the
image
being
observed
).
Press
the
ON
/
OFF
9
button
briefly
to
activate
calibration
.
There
is
no
need
to
close
the
lens
cover
because
an
internal
shutter
covers
the
microbolometer
automatically
.