EasyManua.ls Logo

Purkeys SELECT - Page 15

Purkeys SELECT
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net
SELECT DIAGNOSTIC GUIDE
LED STATUS CONDITION ACTION NEEDED REFERENCE
Solid Green
Charging
with reefer as
source.
Verify that liftgate
battery is charging
(see Charging
Diagnostics section
on page 19).
Slow
Flashing
Orange
Input voltage
from the reefer
cord has
dropped to less
than 12.4 volts.
Determine cause
for low voltage
condition and repair.
Ref #7
Slow
Flashing
Green
Input voltage
from reefer is
between 12.4
and 13.8 volts.
Determine cause
for low voltage
condition and repair.
Ref #7
Rapid
Flashing
Orange
Blown fuse
on the reefer
circuit.
Repair the circuit
and replace the
fuse.
Ref #6
No LED
No voltage
from the reefer
connection.
Determine where
the problem exists
and repair or replace
the circuit.
Ref #7
Green, then
Toggling
Orange and
Repeating
Excessive
voltage drop.
Replace or repair
the source power
and ground wire
harness.
Ref #8