Loading...
20
LED STATUS CONDITION ACTION NEEDED REFERENCE
Solid Green Charging. None.
Slow
Flashing
Green
No charge or
liftgate battery
voltage has not
yet exceeded
13.2 volts.
Allow time for the
liftgate battery to
charge. Check the
DC/DC converter
and circuit
protection.
Testing
the DC/DC
converter
Slow
Flashing
Orange
No charge or
liftgate battery
voltage has not
yet exceeded
12.8 volts.
Allow time for the
liftgate battery to
charge. Check the
DC/DC converter
and circuit
protection.
Testing
the DC/DC
converter
Rapid
Flashing
Orange
Open ground
fuse.
Repair circuit and/
or replace fuse.
Ref #1
No LED
Open circuit
from liftgate
battery positive
and Select
Controller or
disconnected
ground in liftgate
battery box.
Repair circuit, reset
circuit breaker, or
replace fuse.
Ref #2